Chuck Bowser, RCDD, addresses crucial questions about low-voltage systems, covering EMI detection, IP ratings, camera lenses, and safety procedures in this technical deep-dive episode.
• Signs of electromagnetic interference include humming audio, equipment damage, fuzzy screens, ESD shocks, and signal glitches
• Standard installation practices like separation from power cables can often prevent EMI without requiring shielded cabling
• IP ratings use a two-digit system where the first number (0-6) indicates protection against solids and the second (0-8) shows water protection
• Camera lens types include fixed (unchangeable), variable (manually adjustable), zoom (motorized remote control), and multiple (multifocal) options
• Front projection systems require consideration of projector placement, presenter location, screen height, aesthetics, acoustics, and lens selection
• Wire map testing identifies issues like split pairs that continuity testing might miss
• Data center redundancy models range from N (minimum required) to 2N+1 (two complete systems each with spares)
• Lockout tagout procedures prevent injuries during maintenance by ensuring equipment remains powered off
• Never substitute regular grout for proper firestop material as it can damage cables and violate building codes
Join us next Wednesday at 6pm Eastern for more expert low-voltage advice and industry insights.
Support the show
Knowledge is power! Make sure to stop by the webpage to buy me a cup of coffee or support the show at https://linktr.ee/letstalkcabling . Also if you would like to be a guest on the show or have a topic for discussion send me an email at [email protected]
Chuck Bowser RCDD TECH
#CBRCDD #RCDD
5
2828 ratings
Send us a text
Chuck Bowser, RCDD, addresses crucial questions about low-voltage systems, covering EMI detection, IP ratings, camera lenses, and safety procedures in this technical deep-dive episode.
• Signs of electromagnetic interference include humming audio, equipment damage, fuzzy screens, ESD shocks, and signal glitches
• Standard installation practices like separation from power cables can often prevent EMI without requiring shielded cabling
• IP ratings use a two-digit system where the first number (0-6) indicates protection against solids and the second (0-8) shows water protection
• Camera lens types include fixed (unchangeable), variable (manually adjustable), zoom (motorized remote control), and multiple (multifocal) options
• Front projection systems require consideration of projector placement, presenter location, screen height, aesthetics, acoustics, and lens selection
• Wire map testing identifies issues like split pairs that continuity testing might miss
• Data center redundancy models range from N (minimum required) to 2N+1 (two complete systems each with spares)
• Lockout tagout procedures prevent injuries during maintenance by ensuring equipment remains powered off
• Never substitute regular grout for proper firestop material as it can damage cables and violate building codes
Join us next Wednesday at 6pm Eastern for more expert low-voltage advice and industry insights.
Support the show
Knowledge is power! Make sure to stop by the webpage to buy me a cup of coffee or support the show at https://linktr.ee/letstalkcabling . Also if you would like to be a guest on the show or have a topic for discussion send me an email at [email protected]
Chuck Bowser RCDD TECH
#CBRCDD #RCDD
5,405 Listeners
223,937 Listeners
21,280 Listeners
32,535 Listeners
30,665 Listeners
1,006 Listeners
34,109 Listeners
4,710 Listeners
2,242 Listeners
4,319 Listeners
3,679 Listeners
3,860 Listeners
28,406 Listeners
1,179 Listeners