Sign up to save your podcasts
Or


Guillermo Martinez, an Applications Engineer for Polygon US, provides a comprehensive explanation of psychrometric charts, their significance, and how Polygon utilizes them in their work.
Guillermo begins by introducing psychrometric charts as tools used to understand the properties and conditions of air, including temperature, humidity, and energy. He emphasizes that these charts are specific to certain conditions, such as elevation, which affects air pressure and alters the properties of air.
The video focuses on understanding the components of a psychrometric chart. Guillermo explains the x-axis, which represents the dry bulb temperature, the y-axis, which represents the grains per pound or humidity ratio, and the curved lines indicating relative humidity levels.
Guillermo demonstrates how the chart enables Polygon to determine their targets and understand the relationship between outside weather conditions and the desired internal environment. Through psychrometric chart generating software, they overlay weather data accumulated over many years to visualize worst-case scenarios and align them with the desired indoor conditions. This allows Polygon to determine the starting point and make informed decisions based on client specifications or material requirements.
He highlights a typical target of 75 degrees and 50 percent relative humidity, showcasing how this point on the chart provides additional information, such as the grains per pound. Guillermo stresses the importance of considering outside weather data, demonstrating how it influences the project. He explains that Polygon designs systems to manipulate the outside air and achieve the desired indoor conditions.
The video emphasizes the complexity and value of psychrometric charts in understanding air properties and planning environmental control solutions. Guillermo assures viewers that Polygon is ready to engage in detailed discussions with clients, tailoring explanations to their specific needs.
Deanna Talbot, the Director of Marketing at Polygon, introduces a panel of experts who discuss the importance of data and technology in creating healthy and energy-efficient buildings. The discussion is led by David Simkins, the Director of Engineering and Technology, and Frank Dobosz, the President of Polygon in the U.S.
David reflects on the evolution of Polygon's technology over the past three decades, focusing on improving indoor climate control and leveraging new sensors in the indoor air quality market. He explains how the introduction of connected devices and IoT technology, specifically the fifth generation technology called "ExactAire E5," has enhanced Polygon's ability to provide real-time data on space conditions and offer wireless communication between sensors and the cloud.
The panel emphasizes the significance of data in various industries. Regulatory compliance, such as monitoring CO2 levels and gas concentrations in food plants, drives the need for real-time access to actionable data. They highlight how real-time data is crucial not only in the food industry but also in areas like the coatings industry, construction industry, and building envelope specifications. The ability to measure temperature, humidity, and moisture content aids in documenting conditions and preventing issues like mold and mildew.
Frank emphasizes the shift in the construction industry towards building healthier spaces and reducing energy consumption. He discusses how contractors are becoming more educated about managing indoor climates during construction processes, highlighting the importance of optimized humidity and temperature control. The use of engineered solutions and real-time data allows contractors to make informed decisions, order the right equipment, and minimize energy waste.
The panel also addresses the broader impact of Polygon's technology on environmental, social, and governance (ESG) practices. They emphasize how Polygon's focus on energy efficiency, healthy environments, and data-driven decision-making aligns with the triple bottom line concept of people, planet, and profits. By creating mutually beneficial solutions, Polygon aims to support clients in achieving profitability, ensuring the well-being of workers, and reducing the environmental impact of construction processes.
Through their advanced sensors, real-time data analysis, and engineered solutions, Polygon aims to provide clients with optimal indoor climate control, regulatory compliance, and sustainable practices.
Kyle Mattingly, a Project Manager at Polygon in Orlando, Florida, provides a concise overview of desiccant dehumidifiers and their operation.
Desiccant dehumidifiers are introduced as one of the most efficient and effective methods for removing moisture from the air. The central component of these dehumidifiers is the desiccant wheel, also known as a rotor. The desiccant wheel acts like a sponge, absorbing moisture from the air.
Different desiccant materials are used in the construction of the wheel, including lithium chloride, molecular sieve, and silicon gel. The wheel continuously rotates during operation, facilitating the moisture absorption process.
The dehumidification process involves two separate air streams. The first is the process air stream, which is drawn into the dehumidifier through the process inlet. As the air passes through the dehumidifier, the moisture present in the air is absorbed by the desiccant wheel. The dehumidified air exits the dehumidifier through the process outlet, delivering drier air to the conditioned space.
The second air stream is the reactivation air stream, also known as the regeneration air. This air is introduced into the dehumidifier and heated, typically using electric heat elements, gas burners, or steam. The heated air then passes through the desiccant wheel, capturing the accumulated moisture from the wheel. The moisture-laden air is discharged or exhausted outside the dehumidifier.
The video emphasizes the importance of proper understanding and utilization of desiccant dehumidifiers for effective moisture control. It encourages viewers to reach out to the Polygon team for any questions or further information.
Polygon's expertise in desiccant dehumidification technology is highlighted in the video's overview, emphasizing their commitment to providing comprehensive solutions for moisture-related challenges. By explaining the principles of desiccant dehumidifiers, Polygon aims to educate and assist viewers in understanding the benefits and applications of this technology.
Mark Wicker, the Product Manager for Food at Polygon, addresses the issue of ice and condensation buildup in a low-temperature freezer at a poultry facility in Oklahoma.
Polygon's solution for the facility involves the implementation of a pre- and post-cool desiccant dehumidification system, along with other equipment. The system operates at a capacity of 10,000 CFM (cubic feet per minute) to effectively address the ice and condensation issues.
The video showcases a 100-ton chiller that supplies chilled air to the pre-cool air handling unit (AHU) and the post-cool coil. The system combines 50% air from the space with 50% outside air, effectively managing the humidity levels. A 128-shoe fan delivers air to the HC9,000 CFM desiccant dehumidifier, which conditions the air to a low relative humidity (RH) of 5% and a dew point of 2 degrees. The post-cooling process ensures that the air returned to the space maintains the desired conditions, preventing the formation of ice and condensation in the freezer.
Polygon's commitment to delivering effective solutions for their clients is evident in their implementation of the pre- and post-cool desiccant dehumidification system. By addressing the ice and condensation issues, Polygon helps ensure the smooth operation of the poultry facility's low-temperature freezer, contributing to the overall success of their clients' operations in the food industry.
Ideal Conditions pointed its compass east for this episode. When the needle stopped spinning, it landed on two Polygon stalwarts, Larry Waltemire, Business Unit Manager, and Rich Shoemaker, Business Development Manager, helming out of the East Region. Waltemire and Shoemaker have over forty-six years of experience working at Polygon, and there aren’t too many situations they haven’t come across in all that time.
“From disasters to chicken plant needs, to everything imaginable, we’ve seen it all,” Waltemire said. “But every now and then, you get a curveball thrown at you, and you get a new twist on some of the things we’ve done in the past, and we’re able to take from that experience and come up with solutions,” Shoemaker added.
Coming up with those new solutions brought to mind a recent project of a customer with a seven million cubic foot warehouse full of dry products with no humidity control in the building. “It was our job to come up with a solution for that humidity problem,” Waltemire said. “Their main concern was that the product, which was coming in from all over the world, might have an insect larvae hatching that could be in the packing material. It was our job to solve that problem.
Keeping humidity consistently down to less than 50% in a seven million cubic foot building is no small feat. Polygon had to size the solution for a space not yet filled with the product. “Our solution was two, fifteen thousand CFM desiccant dehumidifiers, and those units have three supplies and three returns,” Shoemaker said. “So, we could take air through the unit and put it back into the space. We took six supply ducts, three from each unit, and we spidered those out into the space. We took one duct and ran it over to the loading dock doors because that was the only source of bad air infiltration.”
Polygon showcases their temporary environmental control services provided for the Alexan Gateway project in Kent, Washington, in collaboration with Absure Construction. The editorial overview provides a summary of the key points covered in the video.
Polygon's role in the project is to deliver temporary environmental control solutions to three buildings at the site. They utilize a combination of desiccant dehumidification and gas-fired indirect heaters to create dry and heated air. The focus is on achieving the right air distribution with sufficient velocity and volume to create a positive pressure throughout the building.
The video takes viewers inside one of the buildings, highlighting the stacked desiccant dehumidifiers delivering 10,000 CFM of air. Flex ducts and ten mil polylay flat tubes are used for air circulation, ensuring durability and efficient drying. The strategically placed perforations in the distribution ducting allow dry air to flood the floor space, accelerating drying times for various materials such as joint compound, wood framing, and floor leveling products.
Polygon's centrally located system and temporary ducting enable effective distribution of dry, heated air throughout the construction environment.
The Polygon team introduces their new AQ Plus sensor, highlighting its capabilities in measuring various parameters for clients' indoor air quality.
Polygon emphasizes their ability to measure a wide range of data points using their AQ Plus sensor. This advanced sensor is capable of measuring parameters such as VOCs (volatile organic compounds), temperature, humidity, and particles. The measurement of particles has become increasingly important in environmental control, making it a significant focus for Polygon.
The video highlights the advantages of the AQ Plus sensor and the network it operates on. The sensor is described as quick to deploy and cost-effective, ensuring efficient and affordable monitoring of indoor air quality.
Polygon's commitment to providing comprehensive solutions for their clients is evident, as they continuously strive to offer advanced technologies that accurately measure and assess indoor air quality.
Monitoring hyper-scale data centers require significant planning, understanding of pain points, and innovative solutions. Data center infrastructure management includes tools for monitoring, measuring, and managing data centers. The global DCIM market was estimated at $2 billion in 2022. It is projected to maintain a compound annual growth rate of 11.9% from 2022 to 2026, reaching $2.9 billion.
In this growing market, implementation has evolved considerably, and Polygon is at the forefront of changes. Polygon’s turnkey solutions mitigate risks proactively instead of reactively. “Polygon has the ability to continuously evolve and keep up with all the new developments and the demands from not only the building owners but the general contractors. So we have done a considerable amount of transitioning, improvement, and stellar technology that we’re now currently using,” said Tina York, Polygon’s Director of Client Development.
Though data centers don’t have a lot of internal walls, the expansive spaces include large pieces of equipment. “Now we’re using this lower frequency that is 915 megahertz, and it really penetrates through or finds its way around it so that we can get these sensors that are wireless and battery operated to communicate back to what is called the base station or gateway,” said David Simkins, Polygon’s Director of Engineering and Technology.
The team has seen an increase in clients requesting sensors to detect efficiencies. “We see the movement, and it’s not slowing down, having technology that we can actually bring into a project that supports their goals and carbon reduction footprint. And having the data available to show building owners that they’re being diligent and implementing the right processes is instrumental,” said York. With Polygon’s leak detectors, the sensors can alert stakeholders to issues early. “These areas and the things we’re measuring can get remediated or shut down quite quickly, which means less business interruption, a quicker construction schedule,” said Simkins.
The green effort umbrella includes monitoring air quality so that employees in the center are confident that the air quality is safe. Monitoring consists of a wide range of levels. Alerts are sent to managers via email or text so the team can act quickly. In this episode, learn more about Polygon’s custom DCIM solutions, and subscribe to the podcast wherever you listen.
Host of Ideal Conditions, Tyler Kern, sat down with both Victor Games-Bazan, business unit manager, and Austin Jones, business development specialist, of Polygon’s West division to talk about how the work has been and what special issues the team has to solve.
With the aim of providing insulation for buildings of all types undergoing construction, the West Team has had the interesting experience of working with cities that are often seen as having “perfect weather.”
When talking about a job for the San Diego court house, Games-Bazan said it was an ideal project for showcasing their abilities. “That building was twenty-two stories. We conditioned all of that from beginning to end,” he explained. With a project so large, this process ensured the team met the specifications of those working on the building. “The customer, Turner Construction, actually built us a twenty-two-story scaffold that went up the side of the building, wrapped it in shrink-wrap, insulated it, and that’s what we actually used to distribute the air into the building,” Games-Bazan described.
The USA has many different regions that all have their own ecosystems, which can make construction work a very different operation depending on where it’s being done. Regarding how to deal with the various climate types, Jones said, “Cities in and of themselves can create microclimates, so a downtown metro filled with skyscrapers, those buildings will retain heat and will naturally be a warmer area than somewhere that’s more rural, dense vegetation, away from the coast.” Jones also mentioned that, when working in these cities, his team also does research on weather by looking at historical data to see what the climate has been like in the past, going even as far back as a hundred years.