By Scott D. Weingart, MDScienceMedicineHealth & Fitness
Download on the App Store

episodes

  • COVID Airway Management Thoughts
    This page will serve as the repository of COVID19 airway management thoughts and recommendations. Each time I post something new, it will exist as a separate post for a week and then be merged into this page.
    For the Most Comprehensive Info on COVID19, go to Josh's IBCC Chapter
     
    We are at Risk
    Inutbations

    * El-Boghdadly et al. estimated around 1 in 10 intubations would lead to infection [10.1111/anae.15170]

    Non-Rebreather Masks

    * First10EM

    PPE - What to Wear

    * N95 (add a PAPR if available to the N95)
    * Surgical Mask over N95
    * Goggles that surround eyes with facial contact, face shield, or full joint-replacement-hood with visor (full face coverage desperately preferred)
    * Bunny suit, preferably with hood or disposable fluid-proof gown
    * Something to cover your neck if not in hood
    * If no hooded suit available, disposable cap
    * 2 pairs gloves, 1 under sleeves of bunny suit or gown and 1 over, under-layer gloves would ideally be long cuffed
    * Booties are a big doffing risk, so wear shoes you can disinfect

    Preoxygenation
    All of this is based on no evidence (there are no evidence-based strategies out there)
    Non-Rebreather
    This has been the most recommended strategy in articles/write-ups, but in my mind, it may be the worst of the viable options. To get a decent fiO2, you will need to crank it up to flush rate and I am not sure what effect that will have on the patient’s exhalations becoming aerosolized.
    NIPPV
    This has been panned for potential to increase risk to providers—however, that is predicated on passive exhalation systems (i.e. vents exhalation goes to the environment and has only 1 tube). However, a 2-tube system is a closed circuit. With the addition of 2 viral filters, this may be acceptable in a negative pressure room. It can also be left on during the apneic period with a jaw thrust. Place on CPAP/PSV, leave the PSV at 0, dial up PEEP only if patient’s saturations do not come up with 100% fiO2.

    Critical Note: If you use the vent for preox, you MUST disconnect the vent circuit proximal to the viral filter before removing the mask. Otherwise, COVID will be sprayed all around the room!!!!! See Triple C below.
    High-Flow Nasal Cannula
    Aerosol risk seems no greater than standard NC and is mitigated by surgical mask (https://ccforum.biomedcentral.com/articles/10.1186/s13054-021-03512-w)
    BVM with Viral Filter

    * If you don’t have a vent available
    * Turn BVM flow up to flush rate, higher flows do not translate to patient end of the bvm
    * Place viral filter between BVM stem and mask
    * Ideally, a NIPPV mask should still be placed to allow good seal with you away from the patient or just hold two hands on the mask in a thumbs-forward grip

    from Safer Airways
    * Addition of nasal cannula underneath will allow CPAP with PEEP valve if needed. I would only turn NC up to 4-6 lpm if this used. Often NC fits with no mask leak. More preferable is porting the oxygen through a luer or pressure connection port.

     
    Optimal Preoxygenation
    The first video uses a nasal cannula, the second avoids the NC leading to even less mask leak:
    The Nasal Cannula Video (Next Video avoids using Nasal Cannula)

    EMCrit CPAP Set-Up without the NC

    Here is a Pict
    16 min
  • EMCrit 268 – COVID Airway, Cardiac Arrest, Some Ethical Questions, etc.
    "Triple C" Circuit Disconnects
    May be even higher risk than intubation if you do it wrong
    Confer
    Preplan with your partner
    Clamp
    Either non-marring clamp or clamp around 4x4 or tape on ETT (if disconnecting proximal to viral filter, than you can ignore the clamp)
    Cut Flow
    Put the vent in standby or disconnect the inspiratory limb
    EMCrit CPAP Set-Up without the NC
    See the Video

    Here is a Pict

    Here is a Pict with the 22mm OD Male-to-Male Connector and Corrugated Tubing

    Better way to use the 3-way Stopcock
    I showed in the video that you can use O2 tubing with 3-way stopcock but there is a clean oxygen leak. Bill Murphy, medic extraordinaire, wrote me with a better way. Cut off the fat part of the O2 line. You need to test with your hospital's lines to find out the best place to cut, but once you get rid of protrusion, you can make a tight connection without the multipurpose tube to luer adaptor.


    Video Proving that BVM alone doesn't supply enough forward flow
    and that even on flush-rate doesn't provide dangerous flow to patient to cause aerosol


    Cardiac Arrest
    Your safety then their safety
    Safer Airway Society Guidelines
    By all my SMACC airway buddies

    Prepress Version

    There is also a link to the article as well as printable infographics at the SaferAirways Site
    Now on to the Podcast...
    16 min
  • EMCrit 267 – They are not All Right!! An interview on Hemodynamic Assessment with Mike Patterson
    [featimage]
    Michael Patterson FCICM FANZCA
    Mike is an intensivist anaesthetist in Melbourne. He has spent years thinking about disasters seen in anaesthetics and ICU--most of them are hemodynamic ones. His original interest in this problem stemmed from the death of a young lady having elective gynae surgery, in the setting of anaphylaxis. She had an easily palpable central pulse and reassuring EtCO2 throughout. He was involved late due to issues with arterial access. She died of a hypoxic brain injury solely because her pressure was too low for too long. He has been reflecting on this over the last few years and building up a picture of the problems and the solutions. Subsequently, he had been involved in one patient that died in the setting of a POCUS pulse but inadequate pressure and another young lady who lived despite nearly the same problem occurring as the lady that died.
    Central pulses are almost meaningless
    - We are mostly just feeling a change in pressure

    - Hence 50/10 might feel similar to 120/80

    Central pulses are particularly dangerous in distributive shock where the pulse will be felt strongly below 50/-. This has been my repeated experience. It is easily palpable even in hypovolaemic shock with BP < 60 on occasion - You can’t measure pressure from a central pulse until you place an arterial line
    POCUS Pulse as a Representation of Adequate Pulse
    The use of POCUS to confirm flow in the femoral artery or palpation of a femoral artery pulse is problematic, as you discussed. In your hands (and proper resuscitationists), there will be an arterial line in place very quickly so it is a non-issue. Obviously, those involved in resuscitation should fix their system to achieve this but for lots of reasons that is a problem in many parts of the world (including most Melbourne ED’s/ICU’s).

    The problems with ROSC in the setting of PEA or profound hypotension in general are:

    POCUS pulse has the same problems as a central pulse unless applied to the brachial artery where you can place a manual cuff and visualize the occlusion pressure
    Normal EtCO2
    A normal EtCO2 is not reassuring that the pressure is adequate, as you mention - It is useful to suggest ROSC when it kicks up - It is dangerous as any reassurance in distributive shock where pulmonary perfusion is maintained and EtCO2 often doesn’t drop at all despite BP’s < 50/- - In the cardiac arrest setting, PaCO2 has often risen significantly so an EtCO2 in the 30’s may still represent inadequate perfusion let alone pressure I like your step-wise summary of the progression to ROSC. It is brilliant.

     



    The yellow zone is where all the badness is happening in the anaesthetic world and I wonder if that is true in ED and ICU but we just don’t recognize it (as the patients are sick beforehand so any bad outcome isn’t attributed to the haemodynamic management).

    You explained the problems with this zone excellently but I wonder if people will appreciate the dangers of a POCUS pulse or a palpable central pulse for that matter. I am concerned they will be misused and prolong periods of hypotension. I know you were only talking PEA but the issues are the same in profound hypotension.

    My approach is as follows in the setting of profound hypotension = POCUS pulse:
    Radial Pulse?
    Identify that the radial pulse is rapidly and easily felt before you have a problem - This is obviously irrelevant for those presenting in cardiac arrest - In most other circumstances, if you knew it was strong and easily palpable prior, you can’t end up with confirmation bias - convincing yourself there is no problem. Occasionally it is difficult to locate prior,
    23 min
  • EMCrit Wee – Airway Management of COVID-19


    Today I talk with my RACC partner, Brian Wright about the airway management of COVID-19.
    Resources

    * IBCC on COVID-19
    * Peng et al. for Anesthesia
    * https://jamanetwork.com/journals/jama/pages/coronavirus-alert
    * https://www.esicm.org/resources/coronavirus-public-health-emergency/
    * https://www.who.int/emergencies/diseases/novel-coronavirus-2019/technical-guidance
    * https://www.who.int/publications-detail/clinical-management-of-severe-acute-respiratory-infection-when-novel-coronavirus-(ncov)-infection-is-suspected
    * https://criticalcarereviews.com/index.php/covid-19
    * https://www.nejm.org/coronavirus?query=main_nav_lg
    * https://www.cdc.gov/coronavirus/2019-ncov/hcp/index.html
    * EM Cases
    * Crit Care and Anesthesia Recs
    * SARS Packet

    Unanswered ?s

    * Best PPE
    * How to disinfect equipment (e.g. CMAC cart)

    Now on to the Wee...
    28 min
  • EMCrit 266 – High Sensitivity Troponins with Louise Cullen
    Today on the podcast we discuss High Sensitivity Troponins with Dr. Louise Cullen...
    Professor Louise Cullen
    Louise Cullen is a Senior Staff Specialist in the Department of Emergency Medicine, Royal Brisbane and Women’s Hospital, and an active clinician-researcher with particular interests in acute cardiac diseases, syncope, and cardiac biomarkers. She is widely published in numerous peer-reviewed journal including the Lancet. Her mantra is that “You do not do research for research sake” and as such, clinical redesign and translational research is a key part of her endeavours.
     COI
    Dr. Cullen reports receiving grants from Roche; grants, consultancy fees, and personal fees from Abbott Diagnostics; personal fees from AstraZeneca; and personal fees from Novartis outside of the submitted work.

    We have resolved these conflicts by:

    1. Not speaking of any individual manufacturer's assays

    2. In the US, the manufacturers are eliminating prior assays, thereby obviating the conflict of discussing hsTN (i.e. there will be no purchasing decision on your part--you're getting 'em whether you like it or not)
    High Sensitivity Troponins
    IFCC has released a lab spec sheet on troponins

    Troponin values must be individualized based on your hospital's assay
    ACS Decision Aides

    * IMPACT Trial
    * Comparison of four decision aids for the early diagnosis of acute coronary syndromes in the emergency department
    * MDCalc TMACs
    * MDCALC EDAC
    * HsTNi with decision rules

    Other FOAM

    * EM Topics
    * Hennepin High-Sens Troponin Algorithm

    Now on to the Podcast...
     
    27 min