Listen Later

An unusual digital test equipment from the '70s/'80s Poland. Really well made, and just look at all those LC-513 goodness! Reverse-engineered by yours truly, and now I'm walking you through its internals. It's not the only episode I'll have about it, because I haven't demonstrated it on an actual relay - but there'll be more. Including some additional use cases like measuring the retraction time of a relay being switched off.

0:00 Intro

2:00 Meter Outside
5:25 Taking It Apart
6:30 Nixies and Connections
7:15 Counters and BCD Decoders/Drivers (Keri Out!)
8:40 Control Logic
10:18 Isostat Switches
11:30 Relay Control Part - Two SCRs
13:15 Power Supply
14:23 Reverse-Engineering and Schematics
15:00 Counter/Decoder/Display Part and Reset Logic
18:00 Oscillator and Frequency Dividers
19:12 Contact Latching
23:40 Start/Stop and Solenoid Control Logic
26:47 On-Off SCR Relay Control Circuit
28:38 Power Supply Circuit
30:05 Quick Demo
32:20 Afterword