  • EMCrit Wee – The Philosophy of APRV – TCAV with Nader Habashi

    This is part 2 of the APRV - TCAV series. In part 1, I gave a primer on APRV. In this 2nd episode, I speak with the creator of the TCAV method of APRV, Nader Habashi.
    Nader Habashi, MD, FACP, FCCP



    Department of Trauma Critical Care Medicine, R Adams Cowley Shock Trauma Center, University of Maryland School of Medicine, Baltimore, Maryland, USA




    Dr. Nader Habashi is a Professor of Medicine at the University of Maryland School of Medicine and the Medical Director of the Multi-trauma Critical Care Unit at the R Adams Cowley Shock Trauma Center (STC) in Baltimore, Maryland, USA. He also serves as the Medical Director for the Respiratory Therapy Department of the STC. Additionally, Dr. Habashi is the Medical Director for the Organ Procurement Organizations in Maryland (The Living Legacy Foundation) and Los Angeles, California (One Legacy). He is board certified in the areas of Internal Medicine, Critical Care Medicine, Pulmonary Medicine and Neuro Critical Care Medicine.

    Dr. Habashi’s major study interests include alveolar mechanics and mechanical ventilation, mechanical breath profile and clinical management of organ donors. Dr. Habashi collaborates with Syracuse University Medical Center in large and small animal models.

    COI: Dr Habashi reports presenting at conferences sponsored by or in part by Dräger Medical between 2010 and 2015 for which he received remuneration for honoraria and travel. He is also a founder of Intensive Care On-line Network (ICON) and presented webinars hosted by ICON between 2010 and 2015 and continues to present such webinars and assist clinicians with questions, without any remuneration received. Dr Habashi also reports that he has been issued 2 patents for a ventilation method related to initiating, managing, and/or weaning airway pressure release ventilation and controlling a ventilator in accordance with this method. To date, the patents have not been licensed to any manufacturer and no monetary gain has resulted from the patents.

    Resolution: No specific companies were mentioned in the podcast. All topics were discussed generically.



    APRV-TCAV Recruitment of Alveoli

    Stuff Mentioned

    * Physiology in Medicine: Understanding dynamic alveolar physiology to minimize ventilator-induced lung injury
    38 min
  • EMCrit 270 – COVID19 Respiratory Rescue and Ventilatory Optimization – Airway Pressure Release Ventilation (APRV) Time-Controlled Adaptive Ventilation

    APRV Set-Up at its Simplest


    from the original description: Crit Care Med 1987;15(5):459
    PV Curve


    Setting Tlow


    Study of APRV

    * Zhou et al.

    Theory/Physiology/Reviews of APRV

    * 40635_2016_Article_85
    * document
    * Nieman2018StablizeaBrokenLung
    * 180126.full

    APRV Network
    APRVnetwork.org

    then click on banner for COVID19 rescue to get all of the documents mentioned
    More Stuff

    * broken lung
    * APRV Evolution

    More on EMCrit Site

    * IBCC Chapter on APRV during COVID19

    Now on to the Primer...


     
    26 min
  • EMCrit Wee – Webinar I Gave to Pulm/Crit Care Fellows on Avoiding Intubation and Initial Ventilation of COVID19 Patients
     
    ESICM Webinar Mentioned

    * ESICM Seminar on COVID Ventilation

    Read this to See the Thoughts of Actual Smart People

    * in ICM

    M. Ramzy's Infographic on the Article

    Subtypes of COVID
    Mild

    Silent Hypoxemia (can cause iatrogenic injury when patients are intubated in this phase)

    Indolent- Fine then Not (Intubated or Not-Inflammatory Markers)

    Hyperacute

     
    Cytokine Storm
    Hemophagocytic Lymphohistiocytosis (HLH) Overlap / DIC

     
    PathoPhys
    Loss of hypoxic vasoconstriction

    Micro-thrombotic disease

     
    Avoidance of Intubation
    Tachypnea, hypoxemia, do not seem to be indication

    Mental status, Increased Dyspnea, PaCO2 rising

     
    Progression of Therapies
    NC

    Venti

    NRB+NC

    Hi Flo with Surg Mask

    CPAP—must monitor for excessive WOB

     
    Non-Intubated Proning
    ask them to move

     
    Run them Dry
    but not too dry--must replace external and insensible losses or else badness ensues

     
    How to not kill patients with Intubation
    EMCrit Airway Page

     
    How to Ventilate
    High FiO2 Strategy—Normal Compliance Patients
    8 ml/kg, high fiO2

    keep checking Driving Press and Plat

    Avoid the PEEP Tables

    Driving Pressure <=15

    Proning

     

    Prost/NO

     
    Low Compliance Patients
    6 ml/kg

    Conventional Low Vt PEEP Table

    Driving Pressure > 15
    APRV
    works for either subtype

    if experienced, should be dominant mode of ventilation

     
    Other Meds

    * Heparin
    * Steroids

     
    Here is the Video Version

    Audio Version Here:


     

     

     

     

     

     
    48 min
  • EMCrit 269 – Rationing of Critical Care and Ventilators in COVID19 with Reub Strayer


    In many hospitals ventilators have become a scarce or non-existent resource in the face of the COVID19 pandemic. We need a ethical structure to allocate ventilators and other scarce resources:
    Exclusion Criteria before Entry into Ventilator Allocation Strategies

    * Swiss Intensive Care Society Guidelines

     
    Reub's Adaptation of the NYC Vent Allocation Guideline

    * Strayer Ventilator-Allocation-Protocol
    * Original EMUpdates Post
    * ECOG Calculator


    Original NYC Vent Allocation Guidelines

    * 2015 Update

     
    Publications

    * NEJM Allocating Vent Discussion
    * NEJM Fair Allocation of Scarce Medical Resources in the Time of Covid-19
    * JAMA White & Lo
    * Requests for Potentially Inappropriate Treatments in Intensive Care Units

    Forming a Rationing Team

    * LitFL Post

    Now on to the Podcast...
    25 min
  • EMCrit Wee – Alternatives to Vent Splitting and the Safest Vent Splitting Methods in COVID19
    This Post will be updated as new-information arises
     
    Hospital Non-Invasive Machines can be Adapted for Invasive Ventilation
    Issues:

    Most machines are single tube circuits that allow exhalation from a vented mask. If hooked up to an ETT, you need an exhalation port and it must be proximal to a viral filter. Many of the companies sell circuits purpose-built for this, for example:

    Respironic's Version

    If not, items can be adapted to this use by Respiratory Therapy. Key is anything venting to the environment is filtered
    Home BiPAP/CPAP Machines

    * Same deal as above
    * Sinai's Research Page on Adapting Home CPAP Machines
    * Adapting the V60

    Back-Up Ventilators
    Many chronically vented patients have their primary ventilator and a back-up in their homes. If they want to help, their community, a loan of these back-up ventilators would be helpful.
    Oxygen Powered Commercial CPAP Devices
    Like the Boussignac device, Pulmodyne Go-PAP,

    and similar devices
    Intensive Blog's take on NHS Guidance on CPAP
    Anesthesia Machines

    * APSFASA Anesthesia Machines as ICU Ventilators

    Oxylator
    See the EMCrit Post

    With a PEEP cap in place, these will replace a ventilator
    EMCrit CPAP Set-Up
    can be used for invasive CPAP through an ETT for patients who are awake and spontaneously breathing freeing up the ICU ventilators for patients requiring mandatory breaths.



    see video describing set-up on EMCrit COVID Airway Post

    This will not be as comfortable as a legit machine, but it should get the job done
    Vortran Garbage Disaster Vents

    * Instructional Video

     
    Splitting Non-Invasive CPAP




    Listen to the Wee below for more on this...

    Should work on invasive CPAP as well
    Helmet CPAP

    * Helmet-Based Ventilation

    Splitting Ventilators
    This seems absolutely a last resort situation. SCCM has released a guidance document saying the same:

    * SCCM Statement on Vent Splitting
    * PULMCrit Retort to the SCCM Statement
    * Read Jack Iwashyna take on the issue
    *
    10 min
  • COVID Airway Management Thoughts
    This page will serve as the repository of COVID19 airway management thoughts and recommendations. Each time I post something new, it will exist as a separate post for a week and then be merged into this page.
    For the Most Comprehensive Info on COVID19, go to Josh's IBCC Chapter
     
    We are at Risk
    Inutbations

    * El-Boghdadly et al. estimated around 1 in 10 intubations would lead to infection [10.1111/anae.15170]

    Non-Rebreather Masks

    * First10EM

    PPE - What to Wear

    * N95 (add a PAPR if available to the N95)
    * Surgical Mask over N95
    * Goggles that surround eyes with facial contact, face shield, or full joint-replacement-hood with visor (full face coverage desperately preferred)
    * Bunny suit, preferably with hood or disposable fluid-proof gown
    * Something to cover your neck if not in hood
    * If no hooded suit available, disposable cap
    * 2 pairs gloves, 1 under sleeves of bunny suit or gown and 1 over, under-layer gloves would ideally be long cuffed
    * Booties are a big doffing risk, so wear shoes you can disinfect

    Preoxygenation
    All of this is based on no evidence (there are no evidence-based strategies out there)
    Non-Rebreather
    This has been the most recommended strategy in articles/write-ups, but in my mind, it may be the worst of the viable options. To get a decent fiO2, you will need to crank it up to flush rate and I am not sure what effect that will have on the patient’s exhalations becoming aerosolized.
    NIPPV
    This has been panned for potential to increase risk to providers—however, that is predicated on passive exhalation systems (i.e. vents exhalation goes to the environment and has only 1 tube). However, a 2-tube system is a closed circuit. With the addition of 2 viral filters, this may be acceptable in a negative pressure room. It can also be left on during the apneic period with a jaw thrust. Place on CPAP/PSV, leave the PSV at 0, dial up PEEP only if patient’s saturations do not come up with 100% fiO2.

    Critical Note: If you use the vent for preox, you MUST disconnect the vent circuit proximal to the viral filter before removing the mask. Otherwise, COVID will be sprayed all around the room!!!!! See Triple C below.
    High-Flow Nasal Cannula
    Aerosol risk seems no greater than standard NC and is mitigated by surgical mask (https://ccforum.biomedcentral.com/articles/10.1186/s13054-021-03512-w)
    BVM with Viral Filter

    * If you don’t have a vent available
    * Turn BVM flow up to flush rate, higher flows do not translate to patient end of the bvm
    * Place viral filter between BVM stem and mask
    * Ideally, a NIPPV mask should still be placed to allow good seal with you away from the patient or just hold two hands on the mask in a thumbs-forward grip

    from Safer Airways
    * Addition of nasal cannula underneath will allow CPAP with PEEP valve if needed. I would only turn NC up to 4-6 lpm if this used. Often NC fits with no mask leak. More preferable is porting the oxygen through a luer or pressure connection port.

     
    Optimal Preoxygenation
    The first video uses a nasal cannula, the second avoids the NC leading to even less mask leak:
    The Nasal Cannula Video (Next Video avoids using Nasal Cannula)

    EMCrit CPAP Set-Up without the NC

    Here is a Pict
    16 min
  • EMCrit 268 – COVID Airway, Cardiac Arrest, Some Ethical Questions, etc.
    "Triple C" Circuit Disconnects
    May be even higher risk than intubation if you do it wrong
    Confer
    Preplan with your partner
    Clamp
    Either non-marring clamp or clamp around 4x4 or tape on ETT (if disconnecting proximal to viral filter, than you can ignore the clamp)
    Cut Flow
    Put the vent in standby or disconnect the inspiratory limb
    EMCrit CPAP Set-Up without the NC
    See the Video

    Here is a Pict

    Here is a Pict with the 22mm OD Male-to-Male Connector and Corrugated Tubing

    Better way to use the 3-way Stopcock
    I showed in the video that you can use O2 tubing with 3-way stopcock but there is a clean oxygen leak. Bill Murphy, medic extraordinaire, wrote me with a better way. Cut off the fat part of the O2 line. You need to test with your hospital's lines to find out the best place to cut, but once you get rid of protrusion, you can make a tight connection without the multipurpose tube to luer adaptor.


    Video Proving that BVM alone doesn't supply enough forward flow
    and that even on flush-rate doesn't provide dangerous flow to patient to cause aerosol


    Cardiac Arrest
    Your safety then their safety
    Safer Airway Society Guidelines
    By all my SMACC airway buddies

    Prepress Version

    There is also a link to the article as well as printable infographics at the SaferAirways Site
    Now on to the Podcast...
    16 min
  • EMCrit 267 – They are not All Right!! An interview on Hemodynamic Assessment with Mike Patterson
    [featimage]
    Michael Patterson FCICM FANZCA
    Mike is an intensivist anaesthetist in Melbourne. He has spent years thinking about disasters seen in anaesthetics and ICU--most of them are hemodynamic ones. His original interest in this problem stemmed from the death of a young lady having elective gynae surgery, in the setting of anaphylaxis. She had an easily palpable central pulse and reassuring EtCO2 throughout. He was involved late due to issues with arterial access. She died of a hypoxic brain injury solely because her pressure was too low for too long. He has been reflecting on this over the last few years and building up a picture of the problems and the solutions. Subsequently, he had been involved in one patient that died in the setting of a POCUS pulse but inadequate pressure and another young lady who lived despite nearly the same problem occurring as the lady that died.
    Central pulses are almost meaningless
    - We are mostly just feeling a change in pressure

    - Hence 50/10 might feel similar to 120/80

    Central pulses are particularly dangerous in distributive shock where the pulse will be felt strongly below 50/-. This has been my repeated experience. It is easily palpable even in hypovolaemic shock with BP < 60 on occasion - You can’t measure pressure from a central pulse until you place an arterial line
    POCUS Pulse as a Representation of Adequate Pulse
    The use of POCUS to confirm flow in the femoral artery or palpation of a femoral artery pulse is problematic, as you discussed. In your hands (and proper resuscitationists), there will be an arterial line in place very quickly so it is a non-issue. Obviously, those involved in resuscitation should fix their system to achieve this but for lots of reasons that is a problem in many parts of the world (including most Melbourne ED’s/ICU’s).

    The problems with ROSC in the setting of PEA or profound hypotension in general are:

    POCUS pulse has the same problems as a central pulse unless applied to the brachial artery where you can place a manual cuff and visualize the occlusion pressure
    Normal EtCO2
    A normal EtCO2 is not reassuring that the pressure is adequate, as you mention - It is useful to suggest ROSC when it kicks up - It is dangerous as any reassurance in distributive shock where pulmonary perfusion is maintained and EtCO2 often doesn’t drop at all despite BP’s < 50/- - In the cardiac arrest setting, PaCO2 has often risen significantly so an EtCO2 in the 30’s may still represent inadequate perfusion let alone pressure I like your step-wise summary of the progression to ROSC. It is brilliant.

     



    The yellow zone is where all the badness is happening in the anaesthetic world and I wonder if that is true in ED and ICU but we just don’t recognize it (as the patients are sick beforehand so any bad outcome isn’t attributed to the haemodynamic management).

    You explained the problems with this zone excellently but I wonder if people will appreciate the dangers of a POCUS pulse or a palpable central pulse for that matter. I am concerned they will be misused and prolong periods of hypotension. I know you were only talking PEA but the issues are the same in profound hypotension.

    My approach is as follows in the setting of profound hypotension = POCUS pulse:
    Radial Pulse?
    Identify that the radial pulse is rapidly and easily felt before you have a problem - This is obviously irrelevant for those presenting in cardiac arrest - In most other circumstances, if you knew it was strong and easily palpable prior, you can’t end up with confirmation bias - convincing yourself there is no problem. Occasionally it is difficult to locate prior,
    23 min
  • EMCrit Wee – Airway Management of COVID-19


    Today I talk with my RACC partner, Brian Wright about the airway management of COVID-19.
    Resources

    * IBCC on COVID-19
    * Peng et al. for Anesthesia
    * https://jamanetwork.com/journals/jama/pages/coronavirus-alert
    * https://www.esicm.org/resources/coronavirus-public-health-emergency/
    * https://www.who.int/emergencies/diseases/novel-coronavirus-2019/technical-guidance
    * https://www.who.int/publications-detail/clinical-management-of-severe-acute-respiratory-infection-when-novel-coronavirus-(ncov)-infection-is-suspected
    * https://criticalcarereviews.com/index.php/covid-19
    * https://www.nejm.org/coronavirus?query=main_nav_lg
    * https://www.cdc.gov/coronavirus/2019-ncov/hcp/index.html
    * EM Cases
    * Crit Care and Anesthesia Recs
    * SARS Packet

    Unanswered ?s

    * Best PPE
    * How to disinfect equipment (e.g. CMAC cart)

    Now on to the Wee...
    28 min