We keep building out the podcast studio and use it to test a service low voltage contractors can add fast: anti-static flooring that protects network electronics from electrostatic discharge. We break down where ESD flooring actually makes sense, how to sell the protection instead of the product, and the simple steps to install and bond interlocking tiles to ground.
• why static electricity quietly damages switches, servers, and routers
• how to decide if a telecom room really needs ESD flooring
• positioning anti-static flooring as risk reduction and uptime protection
• what surprised us about floating interlocking tile systems
• prep and layout basics using center lines and directional arrows
• the three simple tools we use to install and cut tiles
• bonding the floor to ground with copper tape and continuity
• a fast cut-and-fit trick for tight walls and corners
• joining TextGiving to upgrade technology for families in need
If you're watching this show on YouTube, would you mind hitting the subscribe button and the bell button to be notified when new content is being produced? If you're listening to us on one of the audio podcast platforms, would you mind leaving us a five-star rating? Would you mind clicking that QR code right there? You can buy me a cup of coffee. You can schedule a 15-minute one-on-one call with me after hours, of course. And you can also buy Let's Talk Cabling Merchandise. You should join us at TextGiving this year. Email Chuck at advertising at letstalkcabling.com and let's connect your brand to the right audience today.
Support the show
Knowledge is power! Visit our webpage to find out ways you can support the show. Also if you would like to be a guest on the show, please complete the application.
Chuck Bowser RCDD TECH
#CBRCDD #RCDD
Send us Fan Mail
We trade quick industry news with practical answers to the questions technicians and new project managers run into every week, from fiber expansion headlines to the details that keep installs clean and safe. We share what we do to reduce rework, tighten project communication, and stay ready for emergencies on site.
• live stream schedule changes and a new “pick one” opener
• NFPA meaning and why it matters in the trades
• fiber optic industry updates on sensing, supply, and 400G growth
• stub up versus stub out definitions for conduit work
• latching duct raceway best practices, adhesives, anchors, and clean cuts
• CPR, first aid, tourniquets, and how Good Samaritan laws reduce risk
• ladder safety fundamentals plus real world transport hazards
• TR drawings, rack elevations, and customer sign-off to prevent changes
• stipulated sum, cost plus, and unit price contract basics
• OBS meaning and why project plans include it
• single mode light sources versus multimode options
• virtual servers explained for data center environments
• fiber optic cable lifespan, moisture migration, brittleness, and OTDR testing
"you can find access how to get into that group by going to let's talk cablining.com forward slash ask dash chuck dash live."
Industry News:
https://corporate.comcast.com/press/releases/comcast-introduces-smart-fiber-sensing-platform-to-further-enhance-industry-leading-network-reliability
https://www.corning.com/worldwide/en/about-us/news-events/news-releases/2026/09/att-and-corning-team-up-to-engineer-the-connected-world-with-fiber.html
https://www.ekinops.com/news/customers/ekinops-powers-bluebird-fiber-s-midwest-network-investments-for-growing-infrastructure-demand
Support the show
Knowledge is power! Visit our webpage to find out ways you can support the show. Also if you would like to be a guest on the show, please complete the application.
Chuck Bowser RCDD TECH
#CBRCDD #RCDD
Send us Fan Mail
We run through 10 fast, field-tested questions that hit the problems installers and designers face when they need answers they can use right away. We connect rules of thumb to real design limits so you can plan cleaner pathways, protect signal quality, and avoid expensive rework.
• sizing underground conduit using cable OD plus pulling eye clearance
• planning pull points beyond the memorized 600-foot spacing for single mode fiber
• decoding firestopping terms like listed, tested, certified and why the UL system drawing matters
• understanding what happens when you connect 62.5 micron fiber to 50 micron fiber
• explaining fiber loss budget math using a simple bank account model
• distinguishing common mode from differential mode interference and why pair balance matters
• choosing open ceiling vs drop ceiling in telecom rooms based on access and cooling needs
• using a patch panel to horizontal wire manager rack unit rule of thumb
• adjusting patch cord allowances when using 28 AWG cords and considering PoE resistance
• keeping power and communications separated inside shared utility columns using barriers and bonding
Make sure you go to Let’s Talk Cabling.com forward slash learn.
Make sure you join the Let’s Talk Cabling crew. Go to Let’s Talk Cabling.com forward slash ask dash Chuck Dash Live.
Send me a message with content you want to see me produce.
Support the show
Knowledge is power! Visit our webpage to find out ways you can support the show. Also if you would like to be a guest on the show, please complete the application.
Chuck Bowser RCDD TECH
#CBRCDD #RCDD
Send us Fan Mail
We break down what fault managed power systems are and why Class 4 “digital electricity” is becoming a real requirement for cabling pros, not a niche curiosity. With Ronna Davis from VoltServer and the FMP Alliance, we connect the code, the cabling, and the jobsite reality so techs and PMs can prepare instead of getting left behind.
• fault managed power defined through NEC 2023 and UL 1400-1 and UL 1400-2 safety standards
• why “limited energy” replaces “low voltage” as voltages rise but fault energy stays controlled
• what actually runs over the pair and why FMPS data is circuit control, not network traffic
• common cable gauges and what changes as FMPS moves toward data centers
• leading applications like small cells, DAS, Wi‑Fi, security, powering IDFs and network enclosures
• addressing fear about scope and focusing on labor shortages and getting more trained hands onsite
• what changes in NEC 2026 and the push toward clearer code organization in future cycles
• design best practices starting with load, power over distance, and centralized power planning
• the transmitter cabling receiver model and why central UPS strategies can cut complexity
• where to get trained through NECA, BICSI, the FMP Alliance, and vendors
• why AI data centers care about power density, footprint, modular scaling, and rapid deployment
• how to follow and join the FMP Alliance and where to learn more from VoltServer
If you're watching this show on YouTube, would you mind hitting the subscribe button and the bell button to be notified when new content is being produced?
If you're listening to us on one of the audio podcast platforms, would you mind leaving us a five-star rating?
Wednesday night, 6 p.m. Eastern Standard Time, what are you doing?
You should join us at TextGiving This Year.
Email Chuck at advertising at letstalkcabling.com and let's connect your brand to the right audience today.
When you click on that QR code right there, you can buy me a cup of coffee.
Support the show
Knowledge is power! Visit our webpage to find out ways you can support the show. Also if you would like to be a guest on the show, please complete the application.
Chuck Bowser RCDD TECH
#CBRCDD #RCDD
Send us Fan Mail
We run through a rapid set of real-world low voltage questions, from multimeter cable length estimates to what your certifier’s “Level 3E” label really means. We also dig into the jobsite choices that quietly drive callbacks, disputes, downtime, and overheated equipment.
• estimating copper cable length with loop resistance and a multimeter, plus what impacts accuracy
• understanding Level 3 vs Level 3E cable certifiers and why backwards compatible is not forwards compatible
• defining the uncertainty zone and why we never accept star pass or star fail results
• troubleshooting marginal certification results through terminations, pair untwist, damage, bend radius, and tester setup
• explaining fiber connector undercut and how it can affect insertion loss and reflectance
• setting practical vertical clearance for stacked cable tray tiers to help today’s install and future adds
• weighing the risks of electrical transformers in telecom rooms, including heat, space, and separation guidance
• preventing OSP cable damage with pulling tension limits, breakaway swivels, grips, bend radius, and inspections
• breaking down mediation vs arbitration and why documentation and change orders matter
• translating asynchronous vs synchronous transmission into plain English examples
• setting fusion splice loss expectations, what to troubleshoot, and why customer specs win
• simplifying redundancy terms N, N+1, N+2, 2N, and 2N+1 with an easy UPS example
• choosing security camera FOV based on distance, resolution, identification goals, and sun position over the year
• managing heat in small enclosed cabinets with PoE switches, UPSs, open space, and fan kits
Make sure you send your questions for next week’s show.
Support the show
Knowledge is power! Visit our webpage to find out ways you can support the show. Also if you would like to be a guest on the show, please complete the application.
Chuck Bowser RCDD TECH
#CBRCDD #RCDD
Send us Fan Mail
We walk through the cable test results that look “fine” until you understand what the graphs are really saying, from split pairs that still link up to length readings that don’t match reality. Along the way, we share practical ways to spot water intrusion, validate extended distance copper, and avoid patch cord mistakes that can quietly break PoE.
• split pairs and transposed pairs causing crosstalk and data loss even with a link light
• cable length vs electrical length plus propagation delay and delay skew for gig speeds
• why NVP settings matter and how faked settings show up in project-wide test reviews
• return loss patterns that point to water in the cable and using HDTDR to locate it
• pulling lubricant vs water symptoms and how insertion loss can improve as lube dries
• extended distance cabling and selecting vendor-specific test limits in the tester
• alien crosstalk testing workflow using saved results, disturbed links, and disturbers
• thin patch cords, PoE risk from rising resistance, and using the correct adapters for patch cord tests
So make sure you join us for this conversation and let me know in the comments below if you enjoyed this episode and should I do more like this?
Email Chuck at advertising at letstalkcabling.com and let's connect your brand to the right audience today.
Support the show
Knowledge is power! Visit our webpage to find out ways you can support the show. Also if you would like to be a guest on the show, please complete the application.
Chuck Bowser RCDD TECH
#CBRCDD #RCDD
Send us Fan Mail
We get hands-on with return loss, impedance, and wiremap faults to show how small physical choices in cable and connectors turn into measurable performance problems. We also share practical ways to use LinkWare and HDTDR diagnostics so you can stop guessing, pinpoint faults faster, and deliver results clients will actually accept.
• using certification testers proactively to validate jacks, patch panels, and install practices before full deployment
• why LinkWare files beat screenshots for troubleshooting and trend spotting across large projects
• what return loss measures and how impedance changes create reflections that hurt gig and multi-gig performance
• why matching cable and connectors as a system improves impedance consistency and throughput margin
• real-world failure example using screw-terminal “Category” wall plates and how HDTDR reveals end spikes
• how over-cinched zip ties and regular spacing distort cable geometry and push return loss into marginal territory
• the “star pass” problem and how codes, standards, best practices, manufacturer rules, and contracts collide
• using HDTDR to localize damage and distinguish return loss issues from crosstalk behavior
• wiremap fault walkthroughs for opens, shorts, and rolled pairs plus what distance-to-fault really means
• why cheap wiremap testers can miss split pairs and create hard-to-explain network problems
• pass-through connector controversy framed as crimper fit, blade maintenance, and workmanship
• why field-terminated IDC connectors can reduce bad crimps and resistance imbalance within a pair
if you have not joined the Let's Talk Cabling crew, do it. Link below.
starting October, we're flipping the schedule. We're going to start doing live streams on Monday night at 6 p.m. And we're going to start doing the podcast on Wednesday night.
We'll see you in Philly at Texgiving October 23rd through the 25th.
Email Chuck at advertising at letstalkcabling.com and let's connect your brand to the right audience today.
Support the show
Knowledge is power! Visit our webpage to find out ways you can support the show. Also if you would like to be a guest on the show, please complete the application.
Chuck Bowser RCDD TECH
#CBRCDD #RCDD
Send us Fan Mail
We share major schedule changes, quick industry updates, and a rapid-fire Q&A that gets honest about what it really takes to pass BICSI exams. We break down what to study first, how the hands-on portion works, and the cabling fundamentals that separate confident techs from guesswork.
• podcast and livestream schedule flip starting October 1
• acronym challenge and what JCAHO stands for
• industry notes on BICSI hiring and upcoming manual updates
• how to prioritize Technician exam study by percentage and impact
• building a realistic study plan and putting concepts into field context
• hands-on exam structure, retest rules, and how to practice under time
• choosing Installer 2 Copper, Installer 2 Fiber, or Technician based on scope
• why splicing is over-feared and what SOL-2 Fiber really tests
• RCDD eligibility options and what counts as design experience
• study hours reality check and why experience can work against you
• what to expect on RCDD test day and how to prepare your brain
• twist rates, crosstalk, shielding types, and what cable markings mean
• category bandwidth, encoding basics, and distance limits in real installs
Reach out to Bixie, apply. If you do, make sure that you tell them Chuck sent you.
Join the LTC crew by clicking on that little QR code up there
Support the show
Knowledge is power! Visit our webpage to find out ways you can support the show. Also if you would like to be a guest on the show, please complete the application.
Chuck Bowser RCDD TECH
#CBRCDD #RCDD
Send us Fan Mail
We walk through what to do when a certification tester returns a fail and why guessing wastes the most time and money. Mike Pennacchi
joins us to break down near-end crosstalk results and show how to prove whether the issue is your settings, your connector, or the cable itself.
• why certification testing matters for manufacturer warranty work
• the three most common reasons a NEXT test fails, starting with the wrong test limit
• how cable type selection can change NVP without changing the test limit
• why you stop after the first failed test and verify the setup screen
• how to read NEXT charts to find the failing pair combination
• how comparing main vs remote results points to which end is bad
• how Fault Info and HDTDX help locate crosstalk along the cable
• pin numbers vs pair numbers and why techs mix them up
• clues for wrong-category connectors and workmanship problems
• when “your cable may be damaged” means replacement, not retermination
• how rare manufacturing defects happen and why spool testing sometimes matters
If you're watching this show on YouTube, would you mind hitting the subscribe button and the bell button to be notified when new content is being produced?
If you're listening to us on one of the audio podcast platforms, would you mind giving us a five-star reading?
Wednesday night, 6 p.m. Eastern Standard Time, what are you doing?
If you find value in this content, will you click on that QR code right there? You can buy me a cup of coffee. You can even schedule a one-on-one call with me after hours, of course. You can even buy Let's Talk Cabling merchandise.
Email Chuck at advertising at letstalkcabling.com and let's connect your brand to the right audience today.
Support the show
Knowledge is power! Visit our webpage to find out ways you can support the show. Also if you would like to be a guest on the show, please complete the application.
Chuck Bowser RCDD TECH
#CBRCDD #RCDD
Send us Fan Mail
Support the show
Knowledge is power! Visit our webpage to find out ways you can support the show. Also if you would like to be a guest on the show, please complete the application.
Chuck Bowser RCDD TECH
#CBRCDD #RCDD