Global Medical Device Podcast powered by Greenlight Guru

3 Systems of Risk for Medical Devices from FDA


Listen Later

Why does the FDA have three systems in place to address and handle risk related to medical devices? Each system serves a different purpose, but are all three actually necessary?

In this episode of the Global Medical Device Podcast, Jon Speer talks to Mike Drues from Vascular Sciences about FDA’s three systems of risk for medical devices and the unique interdependencies and distinctions between them.

Some highlights of this episode include:
  • Three systems for medical device risk from FDA: product classification, significant vs. nonsignificant risk, software level of concern.
  • The FDA’s classification system handles risk by classifying medical devices as Class I, II, or III. The higher the class, the higher the risk. The lower the class, the lower the risk. Yet, risk is a broad subject and there are a ton of exceptions.
  • Also, classification numbers/levels used by the FDA in the United States do not translate in a linear way to those in the European Union (EU) and elsewhere. There are similar systems but different rules that are philosophically different. 
  • The significant vs. nonsignificant risk system focuses on clinical trials for medical devices. All clinical evaluations of investigational devices, unless exempt, must have an approved investigational device exemption (IDE).
  • The software level of concern is important because it determines the level of documentation required for software development. 
  • The default classification for any new medical device is Class III. If it’s a new device, it’s not well-established and the benefits and risks are relatively unknown.
  • When it comes to labeling, say anything as long as you can prove and support it. When technology stays the same but the labeling claim changes, risk changes.  
  • The determination of significant or nonsignificant risk is not made by the FDA or Institutional Review Board (IRB), but the medical device company.
  • The software level of concern consists of Class a, b, and c. Does the software have no possibility of causing injury or damage to health? Is non-serious injury possible? Or, is serious injury or death possible?

Memorable quotes by Mike Drues:

“Theoretically, the classification of your medical device depends on risk. In other words, the higher the class, the higher the risk. The lower the class, the lower the risk.”

“The default classification for any new medical device is Class III, which basically means we set the bar at the highest possible level.”

“Oftentimes in regulation, we do things not because they make sense, but because that’s the way we’ve done them in the past.”  

“The determination of significant or nonsignificant risk is not up to the FDA. It’s not even up to your IRB, or Institutional Review Board, it’s up to the company.”

Links:

FDA - Classify Your Medical Device

FDA - Significant Risk and Nonsignificant Risk

FDA - Software Level of Concern

FDA - Product Code Classification Database

Investigational Device Exemption (IDE)

De Novo Classification Process

Center for Devices and Radiological Health (CDRH)

Requests for Feedback and Meetings for Medical Device Submissions

Mike Drues on LinkedIn

Greenlight Guru Webinar - Advanced Strategies and Tactics for Using the De Novo Pathway

Greenlight Guru Webinar - Understanding the Medical Device Classification System

Greenlight Guru Podcast EP 37: Significant Risk vs. Nonsignificant Risk Devices - What's the Difference? 

Greenlight Guru Academy

The Greenlight Guru True Quality Virtual Summit

Greenlight Guru YouTube Channel

MedTech True Quality Stories Podcast

Greenlight Guru

...more
View all episodesView all episodes
Download on the App Store

Global Medical Device Podcast powered by Greenlight GuruBy Greenlight Guru + Medical Device Entrepreneurs

  • 4.8
  • 4.8
  • 4.8
  • 4.8
  • 4.8

4.8

92 ratings


More shows like Global Medical Device Podcast powered by Greenlight Guru

View all
Nature Podcast by Springer Nature Limited

Nature Podcast

759 Listeners

HBR IdeaCast by Harvard Business Review

HBR IdeaCast

1,870 Listeners

Marketplace by Marketplace

Marketplace

8,637 Listeners

Planet Money by NPR

Planet Money

30,643 Listeners

NEJM This Week by NEJM Group

NEJM This Week

315 Listeners

Bloomberg Businessweek by Bloomberg

Bloomberg Businessweek

435 Listeners

Coaching for Leaders by Dave Stachowiak

Coaching for Leaders

1,463 Listeners

Hidden Brain by Hidden Brain, Shankar Vedantam

Hidden Brain

43,452 Listeners

Bold Names by The Wall Street Journal

Bold Names

1,446 Listeners

The Readout Loud by STAT

The Readout Loud

316 Listeners

BioCentury This Week by BioCentury

BioCentury This Week

30 Listeners

MIT Technology Review Narrated by MIT Technology Review

MIT Technology Review Narrated

256 Listeners

The Rest Is History by Goalhanger

The Rest Is History

13,184 Listeners

Zero: The Climate Race by Bloomberg

Zero: The Climate Race

196 Listeners

NEJM AI Grand Rounds by NEJM Group

NEJM AI Grand Rounds

53 Listeners