Trades Exam Prep

Trades Exam Prep

By Ran Chen, EA, CFP®EducationHow ToCourses
Download on the App Store

Trades Exam Prep episodes

  • EPA 608 Prep 13, Recordkeeping — What Technicians and Owners Must Document
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - The mandatory 3-year record retention period for refrigerant handling activities.
    - Key documentation required from owners of appliances with 50 or more pounds of refrigerant.
    - The distinction between a technician's service invoice and an owner's comprehensive compliance log.
    - How to spot the common exam trick question about illegal "venting records."
    - A mnemonic, "I DATE QR," to recall the essential items a technician must document on a service record.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    4 min
  • EPA 608 Prep 12, Leak Detection Methods — Bubble, Electronic, Ultraviolet, Nitrogen
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - The specific applications and limitations of four primary leak detection methods: soap bubble, electronic, UV dye, and nitrogen.
    - Why you must only use dry nitrogen for pressure testing and the severe dangers of using oxygen or compressed air.
    - Common exam traps, such as how wind affects electronic detectors and the need for manufacturer approval for UV dyes.
    - The importance of calibrating electronic leak detectors and the proper technique for using them effectively.
    - A simple mnemonic, "Never Openly Add Air," to remember the critical safety rule for pressure testing with nitrogen.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    4 min
  • EPA 608 Prep 11, Periodic Leak Inspections — When and How Often
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - The specific leak rate thresholds that trigger mandatory periodic inspections for different appliance types.
    - How to distinguish between the quarterly and annual inspection schedules for commercial, IPR, and comfort cooling equipment.
    - The critical role of the 50-pound and 500-pound charge sizes in determining inspection frequency.
    - How a continuously monitored automatic leak detection system can eliminate the need for manual periodic inspections.
    - The 3-year recordkeeping requirement for all leak inspections and the owner's responsibility for maintaining these records.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    3 min
  • EPA 608 Prep 10, Leak Repair Requirements and the 50-Pound Threshold
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - The 50-pound charge threshold that triggers mandatory EPA 608 leak repair requirements for ozone-depleting substances.
    - The specific annual leak rate thresholds for comfort cooling (10%), commercial refrigeration (20%), and industrial process refrigeration (30%).
    - That owners have 30 days to complete repairs once a leak rate threshold is exceeded, including verification tests.
    - The crucial difference between being exempt from mandatory repair (under 50 lbs) and the universal illegality of venting refrigerant.
    - About the major rule change effective January 1, 2026, which lowers the threshold to 15 pounds for HFC refrigerants under the AIM Act.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    4 min
  • EPA 608 Prep 9, Recover Before Opening — The 0 psi Rule
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - Before opening any high-pressure refrigerant system for service or disposal, you must recover the refrigerant until the pressure reaches a minimum of 0 psig.
    - Intentionally venting refrigerant is a federal crime under Section 608 of the Clean Air Act; never cut a charged line.
    - Understand the critical difference between 0 psig (atmospheric pressure) and a deep vacuum; the exam will test this distinction as a common trap.
    - For small appliances using system-dependent recovery, you must recover 90% of the charge (working compressor) or 80% (inoperative compressor), and may need to apply heat to reach the target.
    - Proper documentation of refrigerant recovery is required for appliance disposal, and new recovery cylinders must be evacuated before their first use.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    4 min
  • EPA 608 Prep 8, Refrigerant Recovery Equipment — System-Dependent vs Self-Contained
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - System-dependent (passive) recovery uses the appliance's own compressor and is only for small appliances (15 lbs or less).
    - Self-contained (active) recovery has its own compressor and can be used on any size system.
    - For small appliances, recovery equipment must be able to capture 90% of the charge with a working compressor or 80% with a non-working one.
    - A common exam trap is applying the 80%/90% recovery percentages to large systems, which instead require specific vacuum levels.
    - An alternative to percentage-based recovery on small appliances is to pull a 4-inch mercury vacuum.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    4 min
  • EPA 608 Prep 7, Recovery, Recycling, and Reclaim — Three Different Things
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - The definition of refrigerant recovery as the simple removal and storage of refrigerant from a system.
    - The critical "same-owner" rule for using recycled refrigerant and why it cannot be sold.
    - How reclamation processes used refrigerant to meet virgin product purity under AHRI Standard 700.
    - The exclusive role of an EPA-certified reclaimer in making used refrigerant legal for resale.
    - How to distinguish between exam question scenarios involving recycling versus reclaiming based on ownership and purity standards.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    3 min
  • EPA 608 Prep 6, The Kigali Amendment and the HFC Phase-Down
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - The Kigali Amendment targets high-GWP HFC refrigerants for their climate impact, not ozone depletion.
    - The U.S. implements the HFC phase-down through the American Innovation and Manufacturing (AIM) Act of 2020.
    - The national goal is a mandatory 85% reduction in HFC production and consumption by the year 2036.
    - A common exam trap is confusing the purpose of the original Montreal Protocol (ozone) with the Kigali Amendment (global warming).
    - The industry is shifting to low-GWP alternatives like HFOs (e.g., R-1234yf), CO2, and hydrocarbons.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    4 min
  • EPA 608 Prep 5, Ozone Depletion Potential (ODP) and Global Warming Potential (GWP)
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - How Ozone Depletion Potential (ODP) is measured against the baseline refrigerant R-11 and is driven by chlorine content.
    - How Global Warming Potential (GWP) is measured against Carbon Dioxide over 100 years and can be thousands of times higher for common HFC refrigerants.
    - The critical exam trap of confusing zero ODP with being environmentally safe, while ignoring a refrigerant's high GWP.
    - The specific ODP and GWP values for key refrigerants tested on the exam, including R-22, R-134a, R-410A, and R-1234yf.
    - A simple mnemonic to separate ODP (Ozone/Chlorine) from GWP (Global/CO2) to quickly answer exam questions correctly.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    4 min
  • EPA 608 Prep 4, CFC, HCFC, and HFC Refrigerants — What's the Difference
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - The key chemical difference (the presence of chlorine and hydrogen) that defines CFCs, HCFCs, and HFCs.
    - Why CFCs have the highest Ozone Depletion Potential (ODP) and were phased out under the Montreal Protocol.
    - The role of HCFCs like R-22 as transitional refrigerants and the importance of the January 1, 2020 production ban.
    - The most common exam trap: Understanding that HFCs have zero ODP but a high Global Warming Potential (GWP), leading to their current phase-down under the AIM Act.
    - A simple mnemonic to quickly recall the environmental impact of each refrigerant class during the exam.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    5 min

About Trades Exam Prep

From the publisher's feed

Trades Exam Prep is a free, daily podcast by OpenExamPrep covering the most in-demand skilled trades licensing and certification exams — including EPA 608 (HVAC refrigerant), FAA Part 107 (drone),…