Trades Exam Prep

Trades Exam Prep

By Ran Chen, EA, CFP®EducationHow ToCourses
Download on the App Store

Trades Exam Prep episodes

  • NATE HVAC Exam Prep 33, Equipment Location Clearances and Service Access
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - How NATE exam questions test NEC 2023 Article 110.26 electrical working space requirements of thirty inches wide by thirty-six inches deep for service panels.
    - Why heat pumps require elevated mounting above local snow depth lines and flood risk elevations to maintain proper defrosting and drainage.
    - The critical distinction between restricted outdoor airflow and confined space combustion air requirements under IMC and NFPA 54 codes.
    - How to avoid common exam traps involving condensate line slope, secondary drain pan float switches, and vibration isolators.
    - Using the CLEAR mental shortcut to quickly verify equipment clearances and service accessibility on test day.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    4 min
  • NATE HVAC Exam Prep 32, Load Calculations Equipment Sizing and Matching
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - Why rule-of-thumb square-footage sizing is strictly rejected on NATE HVAC exams
    - The core differences between ACCA Manual J load calculations and ACCA Manual S equipment selection
    - How ACCA Manual D duct design impacts system static pressure and overall capacity
    - The risks of oversizing cooling equipment including short-cycling and latent capacity loss
    - How to use AHRI performance data certificates to verify properly matched HVAC systems
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    4 min
  • NATE HVAC Exam Prep 31, Pre Installation Planning and Documentation
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - How to resolve conflicts between local building codes, project specifications, and manufacturer installation instructions on the NATE exam.
    - Critical pre-installation checks using equipment schedules, submittals, and material inspection procedures.
    - Rules governing permits, service clearances, and mechanical code compliance before setting equipment.
    - Proper jobsite coordination and Request for Information (RFI) procedures when spatial or structural conflicts arise.
    - Memory shortcuts and test-taking strategies for pre-installation documentation questions.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    4 min
  • NATE HVAC Exam Prep 30, Air Balancing and Comfort Diagnostics
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - How to systematically diagnose room-to-room comfort complaints and thermostat placement issues on the NATE exam.
    - How to measure and interpret Total External Static Pressure (TESP) to isolate supply versus return duct restrictions.
    - How to evaluate temperature split, relative humidity, and building pressure differentials to assess system performance.
    - Step-by-step air balancing procedures using main trunk and branch duct dampers without triggering noise or high static pressure.
    - How to avoid common NATE exam traps like increasing blower speed on high static systems and the STAT diagnostic mnemonic.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    4 min
  • NATE HVAC Exam Prep 29, Comfort Loads and Equipment Operation
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - The distinction between ACCA Manual J load calculations and ACCA Manual S equipment selection.
    - How heat gain, solar radiation, internal loads, and infiltration impact sensible and latent heat loads.
    - Why oversized equipment causes short-cycling and cold, clammy conditions with high relative humidity.
    - The role of diversity factors and envelope characteristics in accurate residential load calculations.
    - The mnemonic phrase Just Select Duct Work for sequencing Manual J, Manual S, and Manual D.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    5 min
  • NATE HVAC Exam Prep 28, Humidity Control and Condensation
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - How oversized cooling equipment leads to short-cycling and elevated indoor relative humidity.
    - The fundamental rule governing surface condensation based on dew point temperatures.
    - Differences in wetted-pad bypass, power, and steam humidification equipment setup.
    - Proper condensate drain traps and slope requirements for negative pressure draw-through coils.
    - How building envelope infiltration impacts seasonal sensible and latent HVAC loads.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    5 min
  • NATE HVAC Exam Prep 27, Ventilation and Outdoor Air
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - How outdoor air ventilation dilutes indoor contaminants according to ASHRAE Standards 62.1 and 62.2.
    - The distinction between positive and negative building pressure, including the safety hazard of atmospheric backdrafting.
    - How Heat Recovery Ventilators (HRVs) and Energy Recovery Ventilators (ERVs) differ in sensible and latent heat transfer.
    - Key economizer control types and how outdoor conditions alter sensible and latent equipment loads.
    - How to accurately calculate mixed-air temperatures and avoid common NATE exam calculation traps.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    5 min
  • NATE HVAC Exam Prep 26, Filtration and Indoor Air Quality
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - The distinction between particulate and gaseous contaminants and why MERV-rated media filters do not remove gases or VOCs.
    - How higher MERV filters and filter loading increase pressure drop and reduce system airflow, leading to equipment issues.
    - Why filter bypass around unsealed frames degrades filtration efficiency and damages internal HVAC components.
    - The three-step IAQ control hierarchy of source control, ventilation, and filtration, and why filtration alone is not a cure-all.
    - Practical exam tips and the mnemonic Stop Vent Filter to solve NATE indoor air quality test questions with confidence.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    5 min
  • NATE HVAC Exam Prep 25, Blowers Fans and Performance Tables
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - Differences between forward-curved and backward-inclined fan blades including overloading characteristics
    - Direct drive vs belt drive speed adjustments and sheave ratio principles
    - How ECM motors adjust torque and RPM under rising static pressure
    - Interpreting fan curves, airflow performance tables, and total external static pressure
    - Applying the three Fan Laws to calculate changes in CFM, static pressure, and motor horsepower
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    4 min
  • NATE HVAC Exam Prep 24, Duct Design Leakage and Distribution
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - How ACCA Manual D equivalent length and fitting friction impact total available static pressure and system airflow
    - The operational effects of supply and return airflow imbalance on building pressure and comfort
    - How return duct leakage increases sensible and latent system heat loads while supply leakage wastes cooling capacity
    - Code requirements for duct insulation, UL 181 vapor retarder sealing, and flexible duct support spacing
    - How zoning dampers affect static pressure and why disconnected returns create combustion safety hazards
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    4 min

About Trades Exam Prep

From the publisher's feed

Trades Exam Prep is a free, daily podcast by OpenExamPrep covering the most in-demand skilled trades licensing and certification exams — including EPA 608 (HVAC refrigerant), FAA Part 107 (drone),…