  • NATE HVAC Exam Prep 23, Airflow CFM and Static Pressure
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - How to measure and calculate total external static pressure by combining supply and return pressure magnitudes.
    - How to determine airflow CFM using manufacturer blower performance tables and speed taps.
    - The fundamental duct calculation formula relating CFM, velocity in FPM, and cross-sectional area.
    - Differences in blower performance between PSC and ECM motors under high static pressure conditions.
    - How to diagnose low airflow issues before mistakenly assuming a system has incorrect refrigerant charge.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    4 min
  • NATE HVAC Exam Prep 22, Sensible Latent and Total Capacity
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - How to differentiate sensible capacity from latent capacity and calculate total system capacity
    - How to calculate the Sensible Heat Ratio using sensible capacity divided by total capacity
    - Why oversized HVAC equipment creates short-cycling issues where acceptable dry-bulb temperature masks high relative humidity
    - Common NATE exam traps involving latent loads, grains of moisture, and wet-bulb versus dry-bulb temperature readings
    - The exam mental shortcut Sensible Shifts the Thermometer, Latent Liquidates Moisture for quick concept recall
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    3 min
  • NATE HVAC Exam Prep 21, Psychrometric Properties of Air
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - Key difference between relative humidity and humidity ratio on NATE exam questions
    - How to locate the saturation curve where dry bulb, wet bulb, and dew point align
    - Calculating total heat removal using enthalpy changes across an evaporator coil
    - Diagnosing humidity and comfort complaints caused by improper airflow or coil temperature
    - A quick mnemonic shortcut to remember how dew point tracks absolute moisture content
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    4 min
  • NATE HVAC Exam Prep 20, Electrical Troubleshooting Sequence
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - How to apply the seven-step electrical troubleshooting sequence from visual inspection through final operational testing.
    - How to systematically test 24V control signals and series safety switches to pinpoint open limits and pressure controls.
    - How to distinguish between open, shorted, grounded, and high-resistance electrical fault patterns on NATE exam schematics.
    - How to use the VIC SLAC mnemonic to quickly recall the correct order of troubleshooting steps during testing.
    - How to avoid common exam traps such as voltage verification before resistance testing and evaluating voltage drops across contacts.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    4 min
  • NATE HVAC Exam Prep 19, Electrical Meter Testing in HVAC Systems
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - How to apply the Live-Dead-Live verification protocol before testing unenergized electrical circuits
    - How to interpret voltage drop across closed versus open contacts on NATE exam scenarios
    - Why isolating components is mandatory during resistance, continuity, and capacitance testing
    - Proper clamp-on ammeter placement to prevent magnetic field cancellation and false zero readings
    - How to test run capacitors and motor insulation using megohmmeters within allowable tolerances
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    5 min
  • NATE HVAC Exam Prep 18, Reading Schematics and Wiring Diagrams
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - How schematics represent all switches and contacts in their de-energized shelf state on NATE exam diagrams
    - The operational differences between line voltage loads and low voltage control circuits
    - Terminal identification standards for thermostats and compressor windings
    - The difference between logical ladder schematics and physical pictorial wiring diagrams
    - How to trace current paths from power rail to common to isolate open safety switches and faulty loads
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    5 min
  • NATE HVAC Exam Prep 17, Thermostats and HVAC Control Logic
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - Core 24-volt thermostat terminal assignments for R, C, W, Y, and G in heating and cooling control loops
    - Crucial differences between O and B reversing valve energization logic for heat pump systems
    - Thermostat fan control behavior in gas furnaces versus electric heating and heat pump applications
    - Structural distinctions between conventional 24-volt relay control logic and digital communicating systems
    - Terminal-to-terminal multimeter voltage reading interpretation for diagnosing open and closed control switches
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    5 min
  • NATE HVAC Exam Prep 16, Relays Contactors Sequencers and Safeties
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - Distinction between relays, contactors, and sequencers in HVAC control applications
    - How normally open and normally closed contacts behave in schematic diagrams
    - Staging electric heating elements and fan operation using timing sequencers
    - Function and series wiring of high limits, pressure switches, and safety interlocks
    - Step-by-step method to trace low voltage control inputs to line voltage load responses
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    5 min
  • NATE HVAC Exam Prep 15, Transformers and Low Voltage Control Power
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - How to calculate maximum secondary amperage using transformer VA ratings and turns ratio formulas
    - The impact of incorrect primary multi-tap wiring on low-voltage output and contactor reliability
    - Requirements for secondary grounding and Class 2 overcurrent protection under NEC Article 725
    - How to accurately interpret meter readings across open fuses and identify common exam trap choices
    - A safe step-by-step troubleshooting sequence to isolate low-voltage shorts without bypassing protection
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep
    5 min
  • NATE HVAC Exam Prep 14, Motors Capacitors and Starting Circuits
    This podcast is made by Ran Chen, who holds an EA license, Insurance and Securities licenses (Series 6, 63, 65), and the CFP® designation. He is passionate about opening access to high-quality exam preparation resources and helping learners prepare more effectively for professional certification exams.
    In this episode you will learn:
    - Key operational differences between shaded-pole, PSC, and ECM motors tested on the NATE exam.
    - How to calculate resistance across common, run, and start terminals to identify compressor connections.
    - Operating principles of potential relays versus current relays, including back-EMF pickup and contact states.
    - Critical rules for capacitor replacement, microfarad sizing, voltage ratings, and dual-capacitor terminal wiring.
    - Safe capacitor discharge procedures using bleeder resistors and motor shaft rotation orientation standard.
    For more free exam prep tools, practice questions, and AI-powered explanations, visit https://open-exam-prep.com/ or YouTube Channel: https://www.youtube.com/@Open-exam-prep