  • The Best HVAC Fan Show EVER!

    In this LIVE event, I was joined by Mark W. Fly, PE with AAON. Mr. Fly has over 40 years of experience as a Researcher, Consulting Engineer, Contractor, and Manufacturer in the HVAC Industry. He holds a Bachelor of Science in Engineering Physics from Missouri State University and is a Licensed Professional Engineer in two states. He is currently the Executive Director of the Norman Asbjornson Innovation Center at AAON, Inc. in Tulsa, Oklahoma, and served as Director of Engineering of AAON for 11 years before taking that position.

    Fans provide the primary transport method for moving thermal energy into occupied spaces in most all cases. Designers need to understand the characteristics and limitations of fans, even if embedded into packaged or self-contained equipment to apply the equipment properly. This presentation covers: Different fan types and their characteristics, Fan curves and fan laws, how to use and apply them, Fan stall and unstable regions of operation, How to select the best fan for the flow.

    Thank you and we hope that you enjoy!

    See all of our videos on our YouTube Channel:  https://www.youtube.com/InsightPartnersHVACTV

    Check out Insight Partners on our Website: www.insightusa.com  

    Connect with me on LinkedIn:  https://www.linkedin.com/in/tony-mormino

    1 hr 25 min
  • Heat Pump Water Heaters, Electrification, and Decarbonization

    In this broadcast, I am joined by Tomas Novillo, Director of Strategic Accounts, Nyle Water Heating Systems, to show how Hot Water Heat Pumps work.

    We also discuss two concepts we keep hearing more often, Electrification and Decarbonization. Like it or not, that seems to be the way segments of the HVAC industry are heading.

    The manufacturing community is starting to adjust, and we are proud to bring you this Live event, Heat Pump Water Heaters, Just the Basics. We will discuss how Heat Pump Water Heaters can be applied in commercial and residential applications and their role in the movement toward electrification.

    Presented by Insight Partners and Nyle Heating Systems. Nyle Systems is a growing, innovative company that develops, manufactures, and sells heat pump-driven, energy-saving products. Specifically, they build industrial equipment for Lumber Drying, Food Dehydration, and Heat Pump Water Heating.

    The product design and manufacturing facility is in Brewer, Maine, just across the river from Bangor, central Maine's economic and cultural center. They are firm believers in the need to build a more sustainable future, including the urgent need to reduce emissions. To switch from fossil fuels to electricity based on renewables, the world requires the electrification of many processes, and that is where Nyle focuses. "At Nyle, our mission is to enable Energy Efficiency and the Electrification of industrial and commercial processes, allowing our customers to transition towards a renewable, sustainable energy system."

    Connect with Tony Mormino and Insight Partners Email: [email protected]

    Visit our website: https://www.insightusa.com/

    Connect with me on LinkedIn: https://www.linkedin.com/in/tony-mormino

    Connect to Insight Partners on LinkedIn: https://www.linkedin.com/company/insightusa

    Visit our YouTube channel: https://www.youtube.com/InsightPartnersHVACTV

    Thank you!

    52 min
  • Why Most DX Systems Fail | Relative Humidity vs. Dew Point

    This podcast discusses the difference between Relative Humidity and Dew Point. This is an audio version of our live stream presentation on LinkedIn and our YouTube channel (Insight Partners HVAC TV). 

    Here is a quick summary of the content. 

    Relative Humidity: Not a good measure of water in the air (absolute humidity). RH is the percentage of how much moisture is in the air vs. how much it can hold. It answers the question “how full is the container”?

    Dew Point: The atmospheric temperature below which water droplets begin to condense and dew can form. This is an accurate measurement of water in the air (humidity). We also look at Dry Bulb, Wetbulb (Illustrating with a Sling Psychrometer), Humidity in Grains/LB of dry air.

    We thank you for listening! 

    Tony Mormino

    https://www.insightusa.com/

    16 min
  • The Ultimate Show Down! Variable Capacity vs. Variable Speed Compressor?

    In this podcast, I discuss the difference between a Copeland Digital Scroll Compressor and a Danfoss Variable Speed Compressor. These two HVAC modulating scroll compressor technologies accomplish similar results but are constructed differently. 

    Watch LIVE Video Here: https://youtu.be/rH-VqoUvtC0?t=38

    The Copeland Scroll Digital offers compressor modulation from 10-100 percent, allowing cooling systems to automatically adjust capacity as needed while reducing energy consumption. This scroll technology allows for precise HVAC system control, is more efficient than on/off compressors, and allows for almost continuous operation during dehumidification modes. Variable-capacity control is accomplished by timing the compression by engaging and disengaging the top scroll while motor speed remains constant. Advantages are efficiency, precise control, very low turn down to 10%, and constant velocity refrigerant allowing for effective oil return. For some of the compressor sizes, the "modulating" can produce unwanted noise. Special considerations for location and attenuation are recommended. 

    Emerson’s Copeland Scroll Variable Speed compressors are designed with AC drive controls that modulate the compressor speed. This compressor speed modulation allows for precise capacity control. Advantages are efficiency, low acoustical characteristics, and precise control. Special considerations are required to ensure oil return which usually prohibits low turndown capabilities. Usually, the minimum allowable turn down is in the 10-25% range.  

    Thank you for listening and please let me know if you have any questions!

    ----------------------------------------------------------------------------------------------------------------------------

    Get in touch with me:

    Call me: 828-712-4769

    Visit our website: https://www.insightusa.com/
    Connect with me on LinkedIn: https://www.linkedin.com/in/tony-mormino 
    View current line card: https://www.insightusa.com/manufactur...
    ----------------------------------------------------------------------------------------------------------------------------

    18 min
  • Grow Room HVAC Basics - Plants Are Not People

    In this episode, I’m super excited to be joined by our own Adam Shaffer, one of the country’s leading experts on Grow Room HVAC design and application.

    You can see the full video version on our YouTube Channel, Insight Partners HVAC TV. 

    https://youtu.be/JQeF6J-cJeI

    Adam has been sizing, selling, and supporting Grow Facilities HVAC systems for many years and will be discussing the challenges associated with these applications. In this audio edition of our live video, we discuss temperature and humidity in grow rooms, dehumidification in grow facilities, maximizing cannabis yield, cleaning water for cannabis, why standard dehumidifiers for grow rooms struggle to keep up, the understanding of vapor pressure differential in grow rooms, grow room temperature control, calculating HVAC loads for grow facilities, optimum humidity for a cannabis plant, how to spot microclimates on your cannabis canopy, ideal grow room temperature and humidity, problems with high humidity in your grow room, controlling your humidity and temperature for indoor cannabis, and much more.

    If you are an Engineer, Owner, or Operator and are having issues with your Cannabis Grow Facility Temperature and Humidity Control please call or emails us. We handle jobs all over the county and are here to help! We specialize in grow room air conditioning and grow room air conditioners. With our equipment and controls experience, we can dial in the Ideal Grow Room Humidity (RH) and Temperature. We can also work with you to determine the ideal temps and RH during all stages of growing. You can email me, Tony Mormino, at [email protected] 

    50 min
  • Do you HEAR what I HEAR? HVAC Acoustics 101 - Getting Back To Basics...

    In this podcast, we're going to explore the importance of Acoustics in HVAC and how it relates to air distribution in the system. This is the audio version of a LIVE online event with our partners at BOSCH Thermotechnologies. 

    Watch Full Video Recoding on our YouTube Channel: https://youtu.be/iUWsKqY_zPo

    Noise is a topic that plays a major role in any HVAC system yet it is a topic that is either misunderstood or not very well understood in the HVAC world. People constantly confuse key terms, definitions, and commonly rated values. 

    Some examples of those terms are sound unit dB vs. dB(A); HVAC Sound Pressure vs. HVAC Sound Power; AHRI 260.2011 vs. AHRI 260.2017, A-Weighted Sound, to name a few.

    So, in this course, we will go back to the basics of sound where we will define commonly used key terms, review the concepts of acoustics and frequency, understand the difference between sound pressure and sound power, and review how sound is measured in the HVAC units. We will wrap up with some case studies which will help to determine how room construction and unit construction can affect the NC (noise criteria) rating of a given room.

    We will also show real-life examples of mitigating HVAC Equipment Noise. 

    Questions? Email Tony Mormino at [email protected]

    Visit our website: https://www.insightusa.com/ 
    Connect with me on LinkedIn: https://www.linkedin.com/in/tony-mormino

    What is a Decibel

    A pressure variation in a sound wave can be measured in micro Pascal's to determine its loudness. The greater the pressure variation there is in a sound wave, the louder it'll be. The micro Pascal is an actual physical measurement of the pressure variation in a sound wave. 
    the weakest sound detectable by the human ear is 20 micro Pascal's. 
    To put this into perspective a pressure change at this level causes the eardrum to displace less than the diameter of a hydrogen molecule. At the same time, the ear can also withstand pressure changes more than a million times this lower threshold. This type of measurement would result in a rather large and awkward scale. To avoid this another scale is used the decibel or DB scale. 

    A-weighted sound in HVAC System Acoustics

    A-weighted sound criteria are commonly used in outdoor sound evaluations - and are often incorporated into city building codes when referencing the maximum acceptable sound pressure levels at the property line. It is popular because it is a single number that most sound meters include.

    The Use of NC Criteria in HVAC Units

    Noise Criteria, or NC, is used as a standard describing or expressing the complexity of relative loudness of a space within a range of frequencies, where the acoustical environment greatly influences the amplitudes and frequencies heard by the occupant. 
    So, simply stated, NC is the Sound Pressure at each Octave Band - with an NC of 35 referenced as the most common noise level specified for HVAC equipment.

    HVAC Sound and Frequency

    The frequency which is measured in hertz is the number of pressure variations that occur per second in a sound wave the sounds frequency produces a distinctive tone. This is why a flute that has a high frequency and a bass drum that has a low-frequency sound is so different. 

    What is the difference between Sound Power vs. Sound Pressure in HVAC Systems?

    SOUND POWER and SOUND PRESSURE are often presented when discussing Acoustics for buildings. Engineers must clearly distinguish and understand the difference between SOUND POWER and SOUND PRESSURE levels.

    AHRI defines SOUND POWER as ACOUSTIC POWER, which is, in a specific frequency band, the rate at which the total airborne sound energy is radiated by a source, measured in watts.

    Simply stated, this means SOUND POWER is the rate at which total Sound Energy is emitted, radiated, reflected, or transmitted by a sound source, per unit time - or basically, WHAT SOUND TH

    1 hr 14 min
  • Another Tool In The Mechanical Engineers Toolbelt | Five Reasons To Consider Vertical Pumps

    In this quick, 20 minute live discussion, Tony and I give you 5 reasons when you may want to consider using Vertical In-line Pumps vs. Horizontal End Suction Pumps. My special guest, Tony Furst, Regional Manager for Armstrong Fluid Technologies, is one of the world leaders in Vertical Pump technology. We will also stick around for live Q & A. Thank you and hope to see you there!

    Watch the video version on our YouTube Channel: https://youtu.be/m_HlHAng4UA

     

    5 Reasons To Consider Vertical Inline (VIL Pumps) Pumps vs. End Suction Pumps:

    INSTALLATION
    Split Coupled Vertical In-Line pumps, being integral components of the pipework, eliminate the need for inertia bases, inertia base springs, flexible pipe connectors, field grouting, and alignment. Pipe hangers sized for the weight of the pump, piping, and fittings are the only supports required. Pipe stools, with vibration isolating pads, may be installed under each pipe leg.

    SPACE-SAVING

    Greatest floor space savings result when Vertical In-Line pumps are installed with Armstrong Suction Guides and Flo-Trex valves. Equivalent base mounted, horizontal split case pumps may take 3 times more floor space.

    MAINTENANCE

    The mechanical seal is the critical service item in any pump. Removal of the Series 4300 split spacer coupling allows all mechanical seal components to be withdrawn for servicing, through the resulting space between the pump and motor shafts, without disturbing other pump components or motor connections. Re-installing the rigid coupling brings the unit rotating assembly back to factory alignment specifications.

    RELIABILITY

    Dynamically balanced impeller and shaft assembly rotating vertically on the Series 4300 centerline translate to a quiet, long-lasting pump with minimum vibration, as static shaft deflection is eliminated. There are no pump bearings to service in the Vertical In-Line design. Series 4300 is a reliable, time-proven unit with less downtime.

    FLEXIBILITY

    Small footprint, low installation costs, reliable, and easy to maintain. These features, combined with a flow range of more than 30,000 USgpm (1,900 L/s),  affirms the Series 4300 as the most flexible pump design available.

     

    Get in touch with me: 

    Visit our website: 
    https://www.insightusa.com/ 
    Connect with me on LinkedIn: 
    https://www.linkedin.com/in/tony-mormino
    View current line card: 
    https://www.insightusa.com/manufacturers
    Connect to Insight Partners on LinkedIn:
    https://www.linkedin.com/company/insightusa
    Visit our YouTube channel: 
    https://www.youtube.com/InsightPartnersHVACTV

    41 min
  • They Sound Alike But Are Way Different | Hot Gas Bypass vs. Hot Gas Reheat

    In this episode, I discuss the importance of knowing the difference between Hot Gas Bypass and Hot Gas Reheat. 

    Check out our YouTube Channel for a video version of this discussion: https://www.youtube.com/InsightPartnersHVACTV

    HOT GAS REHEAT uses the high pressure, high temperature, compressor discharge gas to reheat the air leaving the evaporator coil. This is achieved by running the gas through a hot gas reheat coil using hot gas reheat valves. Hot gas reheat is typically used in dehumidification modes to meet the desired space sensible temperature set point. Modulating hot gas reheat, the more advanced form of reheat, allows us to precisely control the HVAC system leaving air temperature. As opposed to the older style electric reheat, which works well but wastes a lot of energy. Advances in HVAC controls and technology in HVAC systems over the years have made hot gas reheat very popular.

    HOT GAS BYPASS provides an artificial load on the evaporator by introducing a portion of high pressure, high-temperature gas to the evaporator/suction side of the system. An inexpensive and simple way to keep the HVAC system running without freezing the coil but a huge energy waster. The hot gas bypass valve is old technology used on a limited basis today quickly being replaces by modulating compressors or variable capacity compressors. 

    Get in touch with me: 
    Visit our website: 
    https://www.insightusa.com/ 
    Connect with me on LinkedIn: 
    https://www.linkedin.com/in/tony-mormino
    Visit our YouTube channel: 
    https://www.youtube.com/InsightPartnersHVACTV

    11 min
  • How To Read A Psychrometric Chart

    This episode is an audio version of our most popular online event, How To Read A Psychrometric Chart.  You can watch the video version here anytime here > https://youtu.be/b4IVoVP2eeo. 

     

    We discuss Basic Psychrometrics 101.

    Part 1 Properties of Air. We explain the difference between Dry Bulb, Wet Bulb, Relative Humidity, Humidity, and Dew Point.

    Part 2 Building the Psychrometric chart. A psychrometric chart is a graphical representation of the psychrometric processes of air. See how the psychrometric properties make up the chart.

    Part 3 We look at psychrometric processes such as cooling, heating, humidification, dehumidification, cooling, and dehumidification.

    Part 4 Determining Air Properties Part 5 Relative Humidity vs. Dew Point

     

    Hope you enjoy it!!

     

    Get in touch with me: 

    Visit our website: 

    https://www.insightusa.com/

    Connect with me on LinkedIn: 

    https://www.linkedin.com/in/tony-mormino

    Visit our YouTube channel: 

    https://www.youtube.com/InsightPartnersHVACTV

    Thank you and hope you will join us. If you have any questions Tony Mormino can be reached at [email protected].

    29 min
  • Five Tips For Specifying MAU's (Make Up Air Units)

    Since 1997 I've sold a "few" make-up air units and have learned a lot along the way.  In this short episode, I share 5 things to look out for when specifying DOAS systems. 

     

    Get in touch with me: 

    Visit our website: 

    https://www.insightusa.com/

    Connect with me on LinkedIn: 

    https://www.linkedin.com/in/tony-mormino

    Visit our YouTube channel: 

    https://www.youtube.com/InsightPartnersHVACTV

    Thank you and hope you will join us. If you have any questions Tony Mormino can be reached at [email protected].

    14 min

About HVAC TV

From the publisher's feed

HVAC TV, formerly known as The Engineers HVAC Podcast, is the ultimate resource for mechanical engineers, contractors, and service technicians in the commercial HVAC industry. Guided by industry…

More shows like HVAC TV

HVAC School - For Techs, By Techs by Bryan Orr

HVAC School - For Techs, By Techs

1,015 Listeners

Building HVAC Science by Bill Spohn

Building HVAC Science

76 Listeners

Did You Know?-The ESCO HVAC Podcast by ESCO Institute

Did You Know?-The ESCO HVAC Podcast

6 Listeners