
Sign up to save your podcasts
Or


Join the Refrigeration Mentor Hub here
Learn more about Refrigeration Mentor Customized Technical Training Programs at www.refrigerationmentor.com/courses
This episode is another of our live "Morning Coffee" sessions inside our Refrigeration Mentor Community with longtime refrigeration technician, Andrew Freeburg and fellow refrigeration prefessionals. This discussion covers a variety of technical topics including inspecting compressors, proper sensor placement and insulation, particularly for gas cooler outlet sensors, as well as diagnosing system issues such as liquid line frosting due to low refrigerant charge. Interested in joining the next meetup live? Join our FREE Refrigeration Mentor Community today.
In this episode, we cover:
(1:57) Importance of Asking Questions (8:49 Refrigeration Compressor Maintenance (20:57) CO2 Refrigeration System Best Practices (25:07) Importance of Accurate Sensor Readings (26:16) Sensor Placement and Insulation Guidelines (27:42) Manufacturer Recommendations and Testing (29:18) CO2 Refrigeration in Supermarkets and Industrial Settings (30:33) Troubleshooting Frosted Liquid Lines (35:02) Understanding Thermodynamics in Refrigeration (45:45) Community Knowledge Sharing and Training
Helpful Links & Resources:
VIDEO: Scroll Compressor Teardown: What to Watch For
VIDEO: Troubleshooting CO2 Gas Coolers with BAC Part 1: Sensors, ECM Fans, Water Issues & Setup Tips
Episode 17. Troubleshooting the Gas Cooler of a Transcritical CO2 Refrigeration System with Lars Hørup Jensen
Episode 133. Your Compressor Success Guide
By Trevor Matthews5
3131 ratings
Join the Refrigeration Mentor Hub here
Learn more about Refrigeration Mentor Customized Technical Training Programs at www.refrigerationmentor.com/courses
This episode is another of our live "Morning Coffee" sessions inside our Refrigeration Mentor Community with longtime refrigeration technician, Andrew Freeburg and fellow refrigeration prefessionals. This discussion covers a variety of technical topics including inspecting compressors, proper sensor placement and insulation, particularly for gas cooler outlet sensors, as well as diagnosing system issues such as liquid line frosting due to low refrigerant charge. Interested in joining the next meetup live? Join our FREE Refrigeration Mentor Community today.
In this episode, we cover:
(1:57) Importance of Asking Questions (8:49 Refrigeration Compressor Maintenance (20:57) CO2 Refrigeration System Best Practices (25:07) Importance of Accurate Sensor Readings (26:16) Sensor Placement and Insulation Guidelines (27:42) Manufacturer Recommendations and Testing (29:18) CO2 Refrigeration in Supermarkets and Industrial Settings (30:33) Troubleshooting Frosted Liquid Lines (35:02) Understanding Thermodynamics in Refrigeration (45:45) Community Knowledge Sharing and Training
Helpful Links & Resources:
VIDEO: Scroll Compressor Teardown: What to Watch For
VIDEO: Troubleshooting CO2 Gas Coolers with BAC Part 1: Sensors, ECM Fans, Water Issues & Setup Tips
Episode 17. Troubleshooting the Gas Cooler of a Transcritical CO2 Refrigeration System with Lars Hørup Jensen
Episode 133. Your Compressor Success Guide

229,655 Listeners

11,506 Listeners

1,018 Listeners

11,546 Listeners

13,011 Listeners

210 Listeners

46,429 Listeners

14,539 Listeners

87 Listeners

4,475 Listeners

2,400 Listeners

85 Listeners

381 Listeners

17,126 Listeners

6 Listeners