
Sign up to save your podcasts
Or


Prashanthan Sanders, MBBS, PhD, FHRS, University of Adelaide is joined by Jenish Shroff, MBBS, MD, Australian National University, and Pugazhendhi Vijayaraman, MD, FHRS, Geisinger Heart Institute, to discuss this first-in-human feasibility study evaluated a novel helix-based leadless pacemaker (LPCSP) designed to achieve left bundle branch area pacing (LBBAP), a capability current LPs lack. The device was temporarily implanted via the internal jugular vein into the interventricular septum in 14 patients, with successful implantation in 10. Electrical performance metrics, including pacing threshold, R-wave amplitude, and impedance, were within acceptable clinical ranges. LBBAP capture was achieved in 5 patients, with no serious device-related adverse events in 85.7% of cases. The study supports the acute safety and feasibility of LPCSP for conduction system pacing.
https://www.hrsonline.org/education/TheLead https://www.heartrhythmjournal.com/article/S1547-5271(25)02378-1/fulltext
Host Disclosure(s):
P. Sanders: Honoraria/Speaking/Consulting: Boston Scientific, Abbott Medical, Research: Boston Scientific, Abbott, Medtronic, Becton Dickinson, CathRx, Pacemate, Kalyan Technologies, Ceryx Medical, Biosense Webster, Inc., Hello Alfred, Abbott Medical Membership on Advisory Committees: Pacemate, Medtronic PLC, Boston Scientific, CathRx, Abbott Medical
Contributor Disclosure(s):
P. Vijayaraman: Honoraria/Speaking/Consulting: Biotronik, Boston Scientific, Abbott Medical, Medtronic, Inc. Research (Contracted Grants for PIs and Named Investigators only): Medtronic Fellowship Support: Medtronic
J. Shroff: Nothing to disclose.
By The Lead Podcast presented by Heart Rhythm Society5
77 ratings
Prashanthan Sanders, MBBS, PhD, FHRS, University of Adelaide is joined by Jenish Shroff, MBBS, MD, Australian National University, and Pugazhendhi Vijayaraman, MD, FHRS, Geisinger Heart Institute, to discuss this first-in-human feasibility study evaluated a novel helix-based leadless pacemaker (LPCSP) designed to achieve left bundle branch area pacing (LBBAP), a capability current LPs lack. The device was temporarily implanted via the internal jugular vein into the interventricular septum in 14 patients, with successful implantation in 10. Electrical performance metrics, including pacing threshold, R-wave amplitude, and impedance, were within acceptable clinical ranges. LBBAP capture was achieved in 5 patients, with no serious device-related adverse events in 85.7% of cases. The study supports the acute safety and feasibility of LPCSP for conduction system pacing.
https://www.hrsonline.org/education/TheLead https://www.heartrhythmjournal.com/article/S1547-5271(25)02378-1/fulltext
Host Disclosure(s):
P. Sanders: Honoraria/Speaking/Consulting: Boston Scientific, Abbott Medical, Research: Boston Scientific, Abbott, Medtronic, Becton Dickinson, CathRx, Pacemate, Kalyan Technologies, Ceryx Medical, Biosense Webster, Inc., Hello Alfred, Abbott Medical Membership on Advisory Committees: Pacemate, Medtronic PLC, Boston Scientific, CathRx, Abbott Medical
Contributor Disclosure(s):
P. Vijayaraman: Honoraria/Speaking/Consulting: Biotronik, Boston Scientific, Abbott Medical, Medtronic, Inc. Research (Contracted Grants for PIs and Named Investigators only): Medtronic Fellowship Support: Medtronic
J. Shroff: Nothing to disclose.

320 Listeners

497 Listeners

169 Listeners

885 Listeners

3,343 Listeners

140 Listeners

9,132 Listeners

195 Listeners

364 Listeners

430 Listeners

371 Listeners

29,231 Listeners

4 Listeners

3 Listeners

0 Listeners