Danfoss Case Controllers Enables and Control, Does GoogleTranslate Do Scottish?? Episode-508Brett Wetzel and first-time guest Kevin Compass kick off the Advanced Refrigeration Podcast in a chaotic mood after tech failures, traffic, and a rough week on a large grocery-store refrigeration job where electricians are slowing progress, skipping work on energized circuits, and delaying rack startup. They talk about traveling, hotel safety concerns, sleep deprivation, and returning the following week because verification is only partially complete and the rack couldn’t be started. The conversation shifts into Danfoss case control and pack controller details, including correcting earlier misunderstandings about fan shutdown logic being handled automatically by the pack controller if programmed correctly. Brett walks through Danfoss thermostat control settings (on/off vs modulating), notes recommended minimum modulation percentages (around 3.6–4), and discusses guidance from Brian Rogers about avoiding modulating on dual-temp islands unless using an EPR, especially on CO2 systems due to potential icing issues. They explain S3/S4 sensor weighting (inlet vs discharge air), caution against using weighted control where return air can be blocked (turkey, produce, beer cases), and discuss how modulating control can reduce cycling and improve rack stability—especially on low-temp circuits that affect medium-temp load and BGV stability. They debate CO2 ejector versus high-pressure valve operation, with Brett noting updated information that ejectors run as primary until high utilization before the HPV opens. The episode also covers Danfoss network scheduling for case enable/shutdown staging, group-based defrost schedules, why long stage delays can cause short cycling after power blips, the value of adding minimum loop protections, and the confusion of chained controller calculations. They end by noting a potential wiring/relay issue on ejector solenoids (not all on solid-state relays), joking about communication challenges with a Scottish colleague, and signing off as Brett heads to sleep before an early flight.
By Brett Wetzel & Kevin Compass4.8
8585 ratings
Danfoss Case Controllers Enables and Control, Does GoogleTranslate Do Scottish?? Episode-508Brett Wetzel and first-time guest Kevin Compass kick off the Advanced Refrigeration Podcast in a chaotic mood after tech failures, traffic, and a rough week on a large grocery-store refrigeration job where electricians are slowing progress, skipping work on energized circuits, and delaying rack startup. They talk about traveling, hotel safety concerns, sleep deprivation, and returning the following week because verification is only partially complete and the rack couldn’t be started. The conversation shifts into Danfoss case control and pack controller details, including correcting earlier misunderstandings about fan shutdown logic being handled automatically by the pack controller if programmed correctly. Brett walks through Danfoss thermostat control settings (on/off vs modulating), notes recommended minimum modulation percentages (around 3.6–4), and discusses guidance from Brian Rogers about avoiding modulating on dual-temp islands unless using an EPR, especially on CO2 systems due to potential icing issues. They explain S3/S4 sensor weighting (inlet vs discharge air), caution against using weighted control where return air can be blocked (turkey, produce, beer cases), and discuss how modulating control can reduce cycling and improve rack stability—especially on low-temp circuits that affect medium-temp load and BGV stability. They debate CO2 ejector versus high-pressure valve operation, with Brett noting updated information that ejectors run as primary until high utilization before the HPV opens. The episode also covers Danfoss network scheduling for case enable/shutdown staging, group-based defrost schedules, why long stage delays can cause short cycling after power blips, the value of adding minimum loop protections, and the confusion of chained controller calculations. They end by noting a potential wiring/relay issue on ejector solenoids (not all on solid-state relays), joking about communication challenges with a Scottish colleague, and signing off as Brett heads to sleep before an early flight.

229,564 Listeners

12,022 Listeners

153,915 Listeners

1,017 Listeners

7,169 Listeners

11,546 Listeners

28,020 Listeners

2,634 Listeners

75 Listeners

8,748 Listeners

210 Listeners

8,090 Listeners

46,420 Listeners

2,399 Listeners

31 Listeners