Eric Kaiser comes on the live podcast to talk through some commonly repeated EPA myths. We also discuss how to get the most from your recovery machine and tanks. The EPA exists to interpret broad laws into specific standards, such as by translating climate initiatives into venting guidelines.
One of the most common EPA myths is that you cannot charge a leaking system. If you can repair the leak and get the leak rate below the specified percentage, then you can recharge the system. Not every country allows this procedure.
On the subject of refrigerant losses to leaks, making leaks is also NOT a valid excuse to vent refrigerant; the EPA tries to get us to minimize losses as much as possible. De minimis exemptions exist to allow for us to service a system properly, not to give us loopholes for venting. Overall, it's best to use probes to take your readings, not manifolds.
R-22 is another controversial subject that gives rise to some EPA myths. R-22 is NOT illegal, but it is no longer being produced or imported. There are limitations based on the amount of charge as well, but recharging a system with R-22 is NOT a crime.
When recovering with a recovery machine, you want to prevent junk from getting inside of it (such as from the recovery tank). To protect your recovery machine, it's good practice to run the refrigerant through a filter-drier when returning it to a system, though that won't fully clean the refrigerant.
Eric and Bryan also discuss:
Learn more about Refrigeration Technologies HERE.
If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE.
By Bryan Orr4.9
10031,003 ratings
Eric Kaiser comes on the live podcast to talk through some commonly repeated EPA myths. We also discuss how to get the most from your recovery machine and tanks. The EPA exists to interpret broad laws into specific standards, such as by translating climate initiatives into venting guidelines.
One of the most common EPA myths is that you cannot charge a leaking system. If you can repair the leak and get the leak rate below the specified percentage, then you can recharge the system. Not every country allows this procedure.
On the subject of refrigerant losses to leaks, making leaks is also NOT a valid excuse to vent refrigerant; the EPA tries to get us to minimize losses as much as possible. De minimis exemptions exist to allow for us to service a system properly, not to give us loopholes for venting. Overall, it's best to use probes to take your readings, not manifolds.
R-22 is another controversial subject that gives rise to some EPA myths. R-22 is NOT illegal, but it is no longer being produced or imported. There are limitations based on the amount of charge as well, but recharging a system with R-22 is NOT a crime.
When recovering with a recovery machine, you want to prevent junk from getting inside of it (such as from the recovery tank). To protect your recovery machine, it's good practice to run the refrigerant through a filter-drier when returning it to a system, though that won't fully clean the refrigerant.
Eric and Bryan also discuss:
Learn more about Refrigeration Technologies HERE.
If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE.
229,659 Listeners

30,859 Listeners

151 Listeners

75 Listeners

210 Listeners

111 Listeners

725 Listeners

15 Listeners

45,703 Listeners

87 Listeners

85 Listeners

16 Listeners

17,001 Listeners

31 Listeners

6 Listeners